49
System Settings Screen (Admin mode)
(1) System Settings
(top screen)
Used for setting more detailed settings. For details, refer to “7-7 Performing Detailed Settings” (p. 94).
(2) OTHER
OFFSET:
Sets the offset when using AUTO SET.
Z-ESC:
Sets the Z axis lift amount when an error occurs in the HAKKO FU-601 solder feed.
COUNT:
Sets the numerical value for COUNT DOWN shown in work information in the top screen.
(3) Lang
Select the language.
(4) CAMERA
Selects the camera to be used by the system.
(5) SOLDER HEAD ADJUST
Corrects the tip position for tips whose dimension has changed due to wear.
(6) SOLDER HEAD ANGLE
Set the angle matching the mounting angle of
the soldering iron unit.
The tip angle can be changed between 0° and 60°
and mounted. (Refer to diagram at right.)
(7) SOLDER UNIT
Connects to the HAKKO FU-601 and sets the upper limit temperature and lower limit temperature
for the temperature tolerance standard.
(8) I/O MAPPING
Sets the I/O connections for external peripheral equipment such as an emergency stop device, etc.
(9) Operation Mode
Switches the mode to either Admin mode or Operator mode. In Admin mode, all operations can
be performed.In Operator mode, program editing or settings such as cleaning settings, soldering
conditions, etc. cannot be performed. For details on switching modes, refer to “7-7-5-7 Operation
Mode” (p. 115).
7-1-4 System Settings
(2)
(3)
(5)
(6)
(7)
(8)
(9)
(4)
(1)
5°
0º
60
º