4
1. Ethernet
4-5
Netw
Wiring
10BASE-T Connection
•
Cable connection diagram
Straight cable (with HUB)
Cross cable (without HUB)
•
Notes on cables
Use the following recommended cable.
Recommended cable (10BASE-T)
Type: Twist-pair cable, category 5
CU-03
V7i
V7
PLC
HUB
HUB
Distance between the node and the HUB: 100 m maximum
Maximum network nodes:
100 sets
Ethernet
unit
Node
Node
UTP cable
Straight or cross cable
(For more information, refer the HUB specifications.)
UTP cable
Straight
10BASE-T
RJ-45 8Pin
1
2
3
6
4
5
7
8
1
2
3
6
4
5
7
8
10BASE-T
RJ-45 8Pin
1
2
3
6
4
5
7
8
3
6
1
2
5
4
8
7
10BASE-T
RJ-45 8Pin
10BASE-T
RJ-45 8Pin
* Unshielded twist-pair cable
* Unshielded twist-pair cable