Terminate configuration mode by pressing the left button. Display then shows charge state.
After setting make sure to separate connection of plug contact in the dashboard.
Setting parameter:
No.
Battery type
"Charged" profile
"Discharge" profile
7401
4 x 6 V / 240 Ah GiV mainten.-free
2,04
1,76
7408
24V / 420Ah EPzS low-mainten.
2,04
1,73
In the display, three digits for the
discharge profile – discharged
value are flashing (set to
1.73 V/Z in the factory).
Press the right button “
►
“ to increment the discharged value by 0.01 V/Z or hold depressed
for continued incrementing.
After the charged value has been attained, display re-starts automatically with 1.50 V/Z.
After the desired discharged value of the profile has been attained, press the left
button”
▲
/
•
“ once.
73