If a voltage is applied to Pin 1, the bar graph display is activated and the icon appears:
Voltage at PIN 1
Function
0 V
Bar graph and icon (tank indicator) off
Greater than or
equal to 0.5 V
Segment 1 and 2 of the bar graph indicator alternating on / red LED flashing / switching output PIN 3 against
GND
Greater than or
equal to 1 V
Segment 1 and 2 on in alternation
Greater than or
equal to 1.5 V
Segment 1 to 3 on
Greater than or
equal to 2 V
Segment 1 to 4 on
Greater than or
equal to 2.5 V
Segment 1 to 5 on
Geater than or
equal to 3 V
Segment 1 to 6 on
Greater than or
equal to 3.5 V
Segment 1 to 7 on
Greater than or
equal to 4 V
Segment 1 to 8 on
Greater than or
equal to 4.5 V
Segment 1 to 9 on
Greater than or
equal to 5 V
All segments on