226
05-1481-00-00.fm
Maintenance and servicing
5.18.5 Checking the suction mouth sealing strips (2-brush system)
Observe the Safety instructions – Vacuum sweeping system,
see page 222.
Check the sealing strips
of the suction mouth at regular
intervals. Maintenance intervals according to maintenance plan,
see page 167.
Immediately replace defective seals, also on the coarse material
flap
, since the suction power is reduced.
The sealing strips must have a ground clearance of 8.5 +0/-2 mm and
10 +0/-2 mm at the front and at the rear respectively. The coarse material
flap is set to a ground clearance of 20 +0/-5 mm. Loosen the wheel
holders
in order to set the sealing strips.
Note
PU sealing strips (option) must have a ground clearance of
8.5 +0/-2 mm and 10 +0/-2 mm at the front and at the rear
respectively.
Fig. 184:
A
B
8.5 +0/-2 mm
10 +0/-2 mm
C