70
02-1481-00-00.fm
Operation
Display of the hydraulic oil
temperature
The temperature indicator
indicates the temperature of the
hydraulic oil in °C. The font colour of the symbol changes depending on
the temperature. During operation under load, the symbol should light up
green, i.e. the oil temperature is in the optimum operating range.
Interlocking circuit for the work hydraulics
If the temperature exceeds 79 °C, the interlocking circuit for work
hydraulics intervenes:
•
A signal tone is output three times, and a warning symbol is displayed
full-screen for five seconds in the multifunction display.
•
The main consumers of the hydraulics are switched off. If the
temperature falls below 75 °C again, the main consumers can be
switched on again.
Auxiliary functions such as raising, lowering and swivelling the
attachments and the tipper tilt function are not switched off.
Fig. 29:
A
Colour
Message
Remark
White
Temperature low
<30 °C
Green
Temperature in operating
range
30 °C to 75 °C
Red
Temperature over-high
>75 °C
The interlocking circuit for the
work hydraulics intervenes.
Summary of Contents for Citymaster 2200
Page 35: ...02 1481 00 00 fm 35 Operation Fig 3 34 31 29 32 33 34 35 36 37 30...
Page 39: ...02 1481 00 00 fm 39 Operation Fig 5 73 74 71 72 72 71 74 75 76 82 83 84 77 78 79 81...
Page 43: ...02 1481 00 00 fm 43 Operation Fig 7 114 116 117 118 119 120 115 113 112...
Page 236: ...236 05 1481 00 00 fm Maintenance and servicing...