Hand suction hose 1187.01
(optional)
take the following actions when
working with the handheld suction
hose:
Set direction selector to neutral
Engage parking brake
Front lift out system
Lubrication points of the front lift out
system, as shown in the diagram, are
serviced with grease every 75 hours of
operation. Decrease these intervals
when working in salt-laden atmos-
phere.
71
close valve underneath driver's seat
(set lever to "0")
lift hopper by a minor amount and
run engine
use cap out of hardware kit, locate
on hopper inlet (held in place by
suction pressure)
lower hopper; air wont be aspired
through the suction mouth but
through he handheld hose instead
put handheld suction hose off hook
turn suction turbine and water pump
to ON
open water valve on suction pipe
allow suction pipe end to slip over the
ground.
Note :
when job is complete, remove
cap from hopper inlet.
Additional water pump
1182.01 (optional)
this water pump supplies water into
the intake stud of the hopper when
sweeping extremely dry garbage. This
water pump is actuated by a separate
switch (II/9).
This manual does not describe all
options. If these options such as e.g.
winter service are used observe the
instructions of the individual imple-
ments.