Armadillo 6X and AM7D-III PB# 4100043UM Rev. B 07/20
PowerBoss®, Copyright 2014
Page 51
PowerBoss
®
The Power of Clean
5. Allow about 45 seconds for the broom to
operate, then push the main broom switch to the
off position to deactivate and raise the broom.
NOTE: Test time will vary according to the test
surface used.
6. Drive the machine clear of the test site.
7. Examine the polished pattern made by the
broom on the test area.
NOTE: A rectangular shape the length of the
main broom, 2” (5.08 cm) wide, indicates
the main broom is properly adjusted. A
pattern smaller then 2” (5.08 cm) indicates
need for lower adjustment. A pattern wider
than 2” (5.08 cm) indicates a need for
higher adjustment. If pattern is tapered
from end to end instead of rectangular,
see “
Main Broom Taper Adjustment” on
page 53
.
2” (5.08 cm)
Main Broom Test Pattern