Side Broom Lift Cable Adjustment
The lift cable may need to be adjusted if the cable
does not allow the broom to make proper contact with
the fl oor or the broom touches the fl oor when turned
off .
1. Loosen the lock nut.
2. Hold the nyloc nut with a wrench.
3. If the broom touches the fl oor when turned off ,
turn the adjustment screw clockwise to raise the
broom up.
4. If the cable does not allow the broom to make
proper contact with the fl oor turn the adjustment
screw counterclockwise to lower the broom.
5. After the broom lift cable has been properly
adjusted tighten the lock nut.
LOCK NUT
ADJUSTMENT
SCREW
NYLOC NUT