Maintenance and Servicing
5.3.3
Checking the acid level
The customer has to check the acid level of the battery weekly, demineralised
water (according to DIN 43530-4) must be refilled if necessary.
Checking the acid condition:
If the trough battery is equipped with an aquamatic system
Fig. 25-A
, each
individual cell features a sealing plug with float indicator.
The white dot must be located at the top and must be clearly visible. If this is
not the case, refill demineralised water.
Topping up with demineralised water:
Connect the end piece of the aquamatic system
to a container with
demineralised water. Observe sufficient gradient, ensuring the water can flow
into the cells. Once the required filling level has been reached, the plugs auto-
matically seal the cells and indicate “full”
.
Warning
Risk of explosion and fire! When handling batteries, it is prohibited to
smoke and use an open fire.
Attention
• Observe the information in the operating manual
of the battery manufacturer!
• Refilling must only take place once the battery charging process
has been terminated.
Note
Batteries approved by Hako are equipped with an aquamatic
system.