78
05-7180-00.fm
Maintenance and Servicing
5.4
Solution tank
The filling level in the solution tank is measured continuously and shown in the
MFD in steps of 20 %. If there are less than 10 litres in the tank, a warning
symbol appears in the
MFD. At the same time, an acoustic warning
is heard and indicates that a top-up is required.
5.4.1
Filling the solution tank
Fill the solution tank
though the filling opening before commencing
work or as required
.
Filling the solution tank with a hose
1. Place the machine on a level surface.
2. Remove insert in grey cover
Fig. 29-A
.
3. Fill the solution tank up to approx. 15 cm below the maximum filling level
(maximum water temperature 50 °C).
4. Add detergent according to the manufacturer's regulations via the sieve
insert
Fig. 29-B
.
Attention
In order to avoid contamination of the drinking water by backflow,
the requirements of DIN EN1717 must be adhered to for filling the
solution tank.
Note
If the machine is equipped with an on-board dosing system, no deter-
gent must be added to the fresh water!
Fig. 28:
B
A
Fig. 29:
B
A
Summary of Contents for Scrubmaster B175 R