Slide 86
9.
Drive
9.1.2 Service codes DMC control unit - Front
Code
Name
Description
Remedy
Hard Error Faults - Immediately stops pulsing and open line contactor - Cannot be reset (only by a key switch
recycle)
26
Not used
--
--
27
Mosfet shortcircuited to battery minus
Mosfet shortcircuited to battery minus
before Line Contactor is closed;
Motor wiring is interrupted
Check insulating of the motor. If ok,
replace the Drive Control Unit;
Check the wiring between Drive control unit
and Motor for continuity
28 S01
Wire off
Motor Phase Connection
Check Wiring -A04 <=> -M01
28 S02
Wire off
Magnetic Brake short circuit
Check Wiring
28 S03
Wire off
Magnetic Brake wire off
Check Wiring
28 S04
Wire off
Speed sensor wire off
Check Wiring
28 S05
Wire off
Accelerator Wire off
Check Wiring of Hall Sensor -B03
28 S06
Wire off
Motor Thermistor Wire off
Check Wiring
Summary of Contents for Scrubmaster B260 R
Page 64: ...Slide 64 Figure 7 2a Figure 7 2b 7 Mechanical components 7 1 Squeegee...
Page 66: ...Slide 66 Figure 7 4 7 Mechanical components Height adjustment 7 1 Squeegee...
Page 100: ...180 130 170 150 120 Figure 9 5 Slide 100 9 Drive 9 2 4 Steering angle sensor...
Page 121: ...Slide 121 14 Notes...