88
Maintenance and Service
&OHDQLQJWKHGUDLQLQJKRVH
FDS
• Clean the screw cap on the waste
water draining hose (Fig. 26/6) daily.
• Lubricate the O-ring lightly, if neces-
sary.
&OHDQLQJWKHDLULQWDNHILOWHU
The filter sieve (Fig. 29/1) is located in
the recovery tank above the maximum
water level on the suction pipe. The ac-
cumulation of dirt in the filter sieve must
be checked daily and cleaned as nec-
essary:
)LJ
1. Pull the filter sieve from the suction
pipe and clean with water.
Remove the filter sieve com-
pletely to clean it.
During cleaning and operation,
pay attention that no water and
no particles of dirt get into the
suction pipe and into the suc-
tion turbines.
2. Dry the filter sieve after cleaning. Do
not replace when dripping wet!
&OHDQLQJWKHRSHQLQJVWRWKH
VROXWLRQWDQN
The openings between the recovery
and solution tank (Fig. 29/2) serve for
ventilation between the two tanks. They
must be checked regularly for accumu-
lations of dirt and cleaned as neces-
sary.
2
1