67
Maintenance and Servicing
5.7.2
Replacing the sealing strips
Check the sealing strip
Fig. 31-G
and slot strip
Fig. 31-H
at the squeegee
weekly for wear and intactness. If the used sealing edge of the sealing strip is
worn or damaged, turn or replace the sealing strip. Each sealing strip can be
used four times before it needs replacing.
1. Pull out the suction hose
Fig. 30-28.
2. Loosen the star-shaped handles
Fig. 30-A
and remove the squeegee.
3. Press together the protective caps
Fig. 31-I
and pull them out.
4. Loosen the clamping band
Fig. 31-B
and remove it from the catch
Fig. 30-C.
5. Pull out the aluminium body
Fig. 31-J
from the top.
6. Remove the sealing strip
Fig. 31-G
and slot strip
Fig. 31-H
from the plastic
body
Fig. 31-K.
7. Before turning or replacing the sealing strips, thoroughly clean the plastic
body!
8. Assembly is in reverse order.
H
G
J
K
I
B
Fig. 31:
I