23
Elektric system
Service voltage
Mains frequency
Protection class, compl. machine
Protection type, compl. machine
Nominal rating, total, max.
Fuse for brush motor
Fuse for suction motor
Fuse for pump
Brush motor
Suction turbine
Pump
AC/Volt
HZ
EN 60335-2-72
EN 60335-2-72
W
A
A
A
W
W
W
230 ± 10%
50
I
IP X3
1340
5
T 6.3
T 0.5
600
850
16
Noise emission value
The sound pressure level (LpA) (at the ear of the operator) measured
according to DIN IEC 60335-2-72 under normal working conditions:
dB (A)
72
Measurement inaccuracy (KpA):
dB (A)
2
Vibration
The weighted effective value of acceleration, measured in accordance
with ISO 5349-1, to which the upper parts of the body (hand-arm) are
exposed under normal working conditions:
m/s²
< 2,5
The weighted effective value of acceleration, measured in accordance
with ISO 2631-1, to which the upper parts of the body (feet-seat) are
exposed under normal working conditions:
m/s²
< 0,5