56
Maintenance and Care
• Pull dipstick (Fig. 20/3) and check
the hydraulic fluid level, refill if re-
quired.
5.6.2 Refill Hydraulic Fluid
• Unscrew cap with dipstick (Fig. 20/2)
and check hydraulic fluid level, siehe
Abschnitt 5.6.1.
• Use appropriate oil-resistant recipi-
ent with mouth or funnel for refilling.
• Proceed to check of fluid level after
refilling.
• The hydraulic fluid level must not fall
below the minimum. It should read
between the minimum and the maxi-
mum (Fig. 20/).
5.6.3 Change Hydraulic Filter
Change the hydraulic filter according to
maintenance schedule.
For change hydraulic filter proceed as
follows:
• Turn machine off and pull key switch.
• Secure machine by engaging park-
ing brake.
• Open seat hood, loosen and remove
the wing screws of the left side cov-
er.
• Turn hydraulic filter (Fig. 21/1) coun-
ter-clockwise to loosen it and un-
screw.
• Before screwing new filter, fill it with
oil.
• Ride the machine a short distance.
• Refill sufficient hydraulicoil.
• Check fluif filling level.
Fig.21
1