7
8
The
VÜ Nicheless LED Lights
are low voltage light fixtures. Improper wire gauge
and/or wire length can affect the performance of these lights. Follow the guidelines
below to determine the proper operation and optimum performance of the lights.
Voltages are determined by the measured voltage level at the bus bar where the
transformer and cords are connected.
NOTE:
Each color mode has a slightly different power draw.
Cord Length
Min Voltage
Max Voltage
50 feet
9.4VAC
12.4VAC
100 feet
10.7VAC
13.2VAC
150 feet
11.82VAC
13.8VAC
WIRE GUAGE AND LENGTH
WARNING
Which could result in serious injury or death. A Ground Fault Circuit Interrupter (GFCI)
for 120 Volt transformers should be used if required by the transformer manufacturer
or if required by the local state or city code. When a GFCI is used, the cdonductors
on the load side of the GFCI circuit shall not occupy conduit, boxes, or enclosures
containing other conductors unless the additional conductors are also protected by a
GFCI. Refer to local state and city codes for complete details.
RISK OF ELECTRIC SHOCK OR ELECTROCUTION.
WARNING
Which could result in serious injury or death. The
VÜ Nicheless LED Lights
are only available for 12VAC
power. For supply connection, use only an isolating low voltage power supply with ungrounded output,
evaluated and listed by a Nationally Recognized Testing Laboratory (NRTL) for swimming pool use.
RISK OF ELECTRIC SHOCK OR ELECTROCUTION.
WARNING
WIRING TO A SWITCH
*If required by transformer manufacturer's instructions or by local state/city code requirements.
Figure 5:
Wiring
VÜ Nicheless LED Underwater Lights
.
Aqualink
®
Aux Relay or Switch.
Black
Line
GFCI*
Black
White
White
Green
White
Neutral
Ground
Ground
Black
120 volts to 12VAC
transformer.
ColorSplash
®
VÜ
and
PureWhite
®
VÜ Nicheless LED Underwater light fixtures
are
operated through the light’s switch. No special controller or interface is required, Use a
junction box to connect and operate multiple lights with a single switch.
OPERATING THE COLOR SPLASH VÜ & PUREWHITE
VÜ NICHLESS LED UNDERWATER LIGHTS
A 12-14 VAC Transformer must be used to power all 12VAC
VÜ Nicheless LED Lights.
NOTE:
For optimum performance J&J recommends not exceeding the load factor
specified by the instructions included with the transformer.
To ensure maximum safety, only use a transformer that can supply 12VAC and is listed
or certified by a Nationally Recognized Testing Laboratory (NRTL) as compliant with
UL 379, Standard for Power Units for Fountain Luminaires, Swimming Pools and Spas.
12VAC INSTALLATION
To prevent the risk of fire which could result in property damage, void the warranty, as well
as to ensure optimum preformance from your
VÜ Nicheless LED Lights,
do not exceed
the load factor specified in the instructions provided by the manufacturer of the transformer.
WARNING
Summary of Contents for J&J Electronics ColorSplash VU LPL-R1C-12...
Page 16: ...29 30 NOTES NOTA NOTES NOTA...