The

 

VÜ Nicheless LED Lights

 

are low voltage light fixtures. Improper wire gauge 

and/or wire length can affect the performance of these lights. Follow the guidelines 

below to determine the proper operation and optimum performance of the lights.

Voltages are determined by the measured voltage level at the bus bar where the 

transformer and cords are connected.

NOTE: 

Each color mode has a slightly different power draw.

Cord Length

Min Voltage

Max Voltage

  50 feet

9.4VAC

12.4VAC

100 feet

10.7VAC

13.2VAC

150 feet

11.82VAC

13.8VAC

WIRE GUAGE AND LENGTH

WARNING

Which could result in serious injury or death. A Ground Fault Circuit Interrupter (GFCI) 

for 120 Volt transformers should be used if required by the transformer manufacturer 

or if required by the local state or city code. When a GFCI is used, the cdonductors 

on the load side of the GFCI circuit shall not occupy conduit, boxes, or enclosures 

containing other conductors unless the additional conductors are also protected by a 

GFCI. Refer to local state and city codes for complete details.

RISK OF ELECTRIC SHOCK OR ELECTROCUTION.

WARNING

Which could result in serious injury or death. The 

VÜ Nicheless LED Lights

 are only available for 12VAC 

power. For supply connection, use only an isolating low voltage power supply with ungrounded output, 

evaluated and listed by a Nationally Recognized Testing Laboratory (NRTL) for swimming pool use.

RISK OF ELECTRIC SHOCK OR ELECTROCUTION.

WARNING

WIRING TO A SWITCH

*If required by transformer manufacturer's instructions or by local state/city code requirements.

Figure 5:

 

Wiring 

VÜ Nicheless LED Underwater Lights

.

Aqualink

®

 Aux Relay or Switch. 

Black

Line

GFCI*

Black

White

White

Green

White

Neutral

Ground

Ground

Black

120 volts to 12VAC 

transformer. 

ColorSplash

®

 VÜ

 and 

PureWhite

®

 VÜ Nicheless LED Underwater light fixtures

 are 

operated through the light’s switch. No special controller or interface is required,  Use a 

junction box to connect and operate multiple lights with a single switch.

OPERATING THE COLOR SPLASH VÜ & PUREWHITE 

VÜ NICHLESS LED UNDERWATER LIGHTS

A 12-14 VAC Transformer must be used to power all 12VAC 

VÜ Nicheless LED Lights.

NOTE:

  For  optimum  performance  J&J  recommends  not  exceeding  the  load  factor 

specified by the instructions included with the transformer.

To ensure maximum safety, only use a transformer that can supply 12VAC and is listed 

or certified by a Nationally Recognized Testing Laboratory (NRTL) as compliant with 

UL 379, Standard for Power Units for Fountain Luminaires, Swimming Pools and Spas.

12VAC INSTALLATION

To prevent the risk of fire which could result in property damage, void the warranty, as well 

as to ensure optimum preformance from your 

VÜ Nicheless LED Lights,

 do not exceed 

the load factor specified in the instructions provided by the manufacturer of the transformer.

WARNING

Summary of Contents for J&J Electronics ColorSplash VU LPL-R1C-12...

Page 1: ...LIABLE FOR ANY OTHER COSTS OR DAMAGES INCLUDING LOST PROFITS OR REVENUES LABOR CHARGES OR FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES J J reserves the right to change the warranty and or warr...

Page 2: ...llation and or operation will void the warranty Always disconnect the power to the light at the circuit breaker before installing or servicing the light Failure to do so could result in death or serio...

Page 3: ...LED Lights are servicable do not attempt to remove the enclosure of cord from the conduit while submerged No separate ground or bonding wite is required for the V Nicheless LED Lights These lights are...

Page 4: ...f theV Nicheless Lights INSTALLING THE V NICHELESS LIGHT FIXTURE See chart on page 4 for min length requirements 1 minimum rigid conduit No 90 degree elbows 4 Min from water level to top of lens 1 5 P...

Page 5: ...ated and listed by a Nationally RecognizedTesting Laboratory NRTL for swimming pool use RISK OF ELECTRIC SHOCK OR ELECTROCUTION WARNING WIRING TO A SWITCH If required by transformer manufacturer s ins...

Page 6: ...is is normal during the cycling process During this period the pool spa will be dark and precautions should be taken to avoid any unforeseen accidents Failure to observe this warning may result in ser...

Page 7: ...in serious injury or death The V Nicheless LED Lights are only available for 12VAC power For supply connection use only an isolating low voltage power supply with ungrounded output evaluated and liste...

Page 8: ...L RECURSO EXCLUSIVO DEL COMPRADOR EN LUGAR DE OTRAS GARANT AS EXPRESAS O IMPL CITAS INCLUYENDOTODAS LAS GARANT AS DE COMERCIABILIDAD PARA UN FIN PARTICULAR YTODAS LAS GARANT AS DERIVADAS DE NEGOCIACI...

Page 9: ...El ctrico Nacional NEC Antes de instalar este producto lea y siga todas las advertencias e instrucciones incluidas El incumplimiento de las advertencias e instrucciones puede resultar en da os a la pr...

Page 10: ...ctrico de la piscina spa o fuente cumple con todos los requisitos del art culo 680 22 del C digo El ctrico Nacional NEC y los c digos y ordenanzas locales aplicables Un electricista profesional certi...

Page 11: ...Tubo de 1 5 a trav s de las vigas de uni n y una longitud m nima para cada estilo de luz Vea Espect culos de luz p g 4 Conducto el ctrico r gido de 1 Los codos deben ser abiertos o curvos no de 90 Las...

Page 12: ...LONGITUD DEL CABLE ADVERTENCIA Los voltajes son deerminados por el nivel de voltaje medido en la barra de bus a la que el transformador y los cables est n conectados NOTA Cada color tiene un consumo...

Page 13: ...l interruptor de la luz No se requiere ning n controlador o interfaz especial Utiliza una caja de conexiones para conectar y operar m ltiples luces con un solo interruptor OPERAR LAS LUCES SUBACU TICA...

Page 14: ...l siguiente 4 MAREMOTO 6 CIELOS DEL DESIERTO 5 SUE O PATRIOTA Espect culo Cambios r pidos entre colores al azar Ciclo La luz permanecer en cada color durante 2 segundos antes de cambiar al siguiente 7...

Page 15: ...fuente de alimentaci n de 120VCA en el transformador Compruebe si hay salida de 12VCA en el transformador Compruebe o reinicie el interruptor diferencial GFCI Aseg rese de no haber usado 120 voltios...

Page 16: ...29 30 NOTES NOTA NOTES NOTA...

Reviews: