background image

Service Instructions (cont’d)

4/03  ART ONLY L31196

North American Sales Division

Haldex Limited

525 Southgate Drive, Unit 1

Guelph, Ontario Canada N1G 3W6

Phone: 519-826-7723

Fax: 519-826-9497

North American Sales Division

Haldex Brake Products Corporation

10707 NW Airworld Drive

Kansas City, MO 64153-1215

Phone: 816-891-2470

Fax: 816-880-9766

Haldex Commercial Vehicle Systems

www.haldex.com · www.hbsna.com

Step 3:

Place the O-Ring/poppet 

assembly into the check valve body, O-Ring
end first, as shown. Needle nose pliers may
be used to guide the poppet into place.

Step 4:

Place the new spring in back of

the poppet (with small end of spring facing
poppet).

Step 5:

Install retaining ring in retaining

ring groove behind the spring. Following
installation, verification of valve operation
may be desired. Remove the air dryer 
cap assembly and push the nose of the
poppet several times. Free movement with
a positive return should be observed. After
functional testing, the spring must still be
retained fully by the retaining ring.

Other service kits include desiccant refill
kit (Bulletin L31083) and purge valve
service kit (Bulletin L31093).