STABILITY MODULE
INSTALLATION/SERVICE
GUIDE (L31288W)
TM
Plumbing Requirements
General Plumbing Information
›
Actual hose sizes need to be optimized for individual trailer response time requirements
›
Some hoses have defined minimum diameters and maximum lengths as defined in subsequent
plumbing schematics
›
All hoses to comply to recognized international standards
›
Nylon tube to SAE J844, rubber hose to SAE 1402
›
The referenced sizes are defined as guidelines only
›
For optimum performance all hose lengths should be as short as possible
Hose Fittings
Avoid elbows as much as possible. If essential, use
swept type elbow.
Inside diameter of fitting should be the same as
the inside pipe diameter it is serving.
Note:
NEVER USE tape (PTFE) during the installation of
the ITCM Stability Module. Warranty claims will
not be accepted from tape induced faults.
Page 12