SmartFOAM
CHECK VALVE / INJECTOR FITTING
The Hale check valve/injector fitting, supplied with the
Hale SmartFOAM system, meets NFPA requirements for
a non-return device in the foam injection system. It pre-
vents back flow of water into the foam concentrate tank.
When properly installed the brass and stainless steel
construction check valve/injector fitting ensures foam
concentrate is injected into the center of the water flow
for better mixing.
Note: Always position the check valve/ injector fitting at
a horizontal or higher angle to allow water to drain away
from the fitting (Figure 37). This avoids sediment de-
posits or the formation of an ice plug.
The check valve/injector fitting MUST be mounted in a
location that is common to all discharges which require
foam concentrate (
The Hale SmartFOAM system DOES NOT permit a sep-
arate injection point for each foam capable discharge.
However, when running Dual Pump (2) mode, the 2 in-
jection points must be installed on separate manifolds
since the pumps are designed to function independently.
The check valve/injector fitting has – 1” NPT (25.4 mm)
threads on the outside, to fit into the 1” NPT threaded
connection on the Hale mini manifold a pipe tee, or a 1”
NPT weld fitting installed in the discharge piping of the
fire pump (
The inlet connection of the check valve/ injector fitting
uses a 1/2-in NPT female thread.
Figure 37: Check Valve Injector Fitting Installation
Summary of Contents for MiniCAFS 2.1A
Page 3: ...Page 2 SmartFOAM NOTES...
Page 16: ...Page 15 SmartFOAM SYSTEM DIAGRAM Figure 6 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Page 17: ...Page 16 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Page 18: ...Page 17 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Page 19: ...Page 18 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Page 20: ...Page 19 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainers...
Page 21: ...Page 20 SmartFOAM Figure 11 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Page 22: ...Page 21 SmartFOAM Figure 12 SmartFOAM 3 3 5 0 6 5 Dual Tank withADTandIn lineStrainers...
Page 23: ...Page 22 SmartFOAM Figure 13 SmartFOAM 3 3 5 0 6 5 Dual Tank withADTandFSSeries Strainers...
Page 48: ...Page 47 SmartFOAM Figure 28 Typical 4 Inch Check Valve Installation Midship Pump...
Page 59: ...Page 58 SmartFOAM Figure 43 ADT Option Air Hose Connections Part 2...
Page 68: ...Page 67 SmartFOAM Figure 55 Top Mount Low Level Sensor Assembly...
Page 77: ...Page 76 SmartFOAM NOTES...
Page 90: ...89 Page 89 SmartFOAM NOTES...