22
...
...
...
Service Procedures and Adjustments
Electrical Control Test Procedures
1. Remove jug.
2. Remove the power supply plug from the wall socket. Check that the electrical cable is in
good condition and has no cracks. A damaged electric cable must be replaced.
3. Connect the power supply to the wall socket.
4. Turn the variable speed control and check that the machine will not start. Turn the
variable speed control to “0”.
5. Press the pulse button and check that the machine will not start.
6. Install the jug, open the lid, turn the variable speed control and check that the machine
will not start. Turn the variable speed control to “0”.
7. Close the lid, turn the variable sped control and check that the machine will start. Open
the lid and check that the machine stops.
8. If anyoftheabovesafety functions are not in good working order, the machine must be
repaired before put back in operation.