General information
The BG02-EIP module provides EtherNet/IP connectivity for the System 300/310 tightening
controllers. It acts as a gateway between the EtherNet/IP master (scanner) and a Profibus Interface
card plugged into the System 300/310. The following picture shows the general system structure:
PLC
SE/KE
EtherNe
t/IP
SMpdp
BG02
1.2
Technical data
Ethernet-Interface
Ethernet
Ethernet 802.3 10/100MBit interface, automatic 10/100MBit detection
EtherNet/IP
EtherNet/IP adapter device
Minimal I/O update rate 20ms
IMpdp/SMpdp-Interface for SE/KE tightening system
IMpdp/SMpdp
Compatible to System 300/310 SMpdp and CS351 IMpdp
Automatic detetion of KE/SE’s PLC-Configuration data mapping
Up to 240 bytes I/O
Electrical characteristics
Power supply
24VDC, provided by SE/KE over internal slot connector
Power req.
ca. 2W
Environment
Temperatur
Allowed ambient temperature in operation 0°C bis 55°C
Allowed ambient temperature for storage -20°C bis +70°C
Humidity
Allowed humidity 20%-70%
Mechanical
Dimensions
(W*H*D)
24 * 81 * 207 mm
3
Connectors
DSUB9 female for IMpdp/SMpdp connection (by cable)
RJ45 for Ethernet