Overview
2
1.3
Mounting instructions
1.3.1
Inserting into the tightening system
The module is inserted into any free interface slot of the system component KE3xx or SE3xx. The
module only uses the internal system connection for power supply, there are no other internal
connections and therefore no special configuration in BS300 required.
Before inserting the interface module, the BT300 card rack must have been voltage-
free for at least 3 min.
Please take care that the interface module is completely inserted. The front knurled bolts must be
tightened and fastened securely. Please take care that the front blind fits closely to BT300.
The module's power supply ensues directly via the control unit. Only the data interface is accessable
from the exterior.
1.3.2
Connecting with the SMpdp/IMpdp module
Use the supplied cable to connect the BG02-EIP to the SMpdp module. If the cable is too short, us a
standard Profibus-type cable to connect BG02-EIP X1 with SMpdp.
1.4
Interfaces
The following picture shows the available front panel interface connectors:
X
2
A
B
X
1
BG02-EIP
1.4.1
X1 IMpdp/SMpdp
Connector X1 is a 9-pin DSUB type socket (female). The pinout is as follows:
X2 (male) Pin Signal io Beschreibung/Funktion
1
-
-
Not connected
2
-
-
Not connected
3
TxRx+ io RS485 positive signal line
4
-
-
Not connected
5
GND
-
Reference ground for pins 3 and 8
6
VP
o +5V terminator supply
7
-
-
Not connected
8
TxRx-
io RS485 negative signal line
9
-
-
Not connected