12
UNDERWRITERS LABORATORIES TESTING
This equipment has been tested and found to comply with the limits for a
Class B
digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from the receiver.
• Consult the dealer or an experienced radio/TV technician.
ELECTROMAGNETIC COMPATIBILITY
Underwriters Laboratories, Inc. reports apply only to the specific samples tested under stated
test conditions. All samples tested were in good operating condition throughout the entire test
program. It is the manufacturer's responsibility to assure that additional production units of
this model are manufactured with identical electrical and mechanical components.
Underwriters Laboratories Inc. shall have no liability for any deductions, inferences, or general-
izations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This
report shall not be used to claim, constitute, or imply product certification, approval, or
endorsement by NVLAP, A2LA, or any agency of the US government. This report may contain
test results that are not covered by the NVLAP or A2LA accreditation. The scope of accredita-
tion is limited to the specific tests that are listed on the NVLAP and/or A2LA certificates provid-
ed at the end of this report.
Test Name
Test Requirement / Specification
complies
does
not
comply
1 Radiated Disturbance Emissions - 30 to 1000 MHz Electric Field
EN 55022:1998 Class B / EN 55022:1998 Class B
2 Conducted Disturbance Emissions - Voltage
EN 55022:1998 Class B / EN 55022:1998 Class B
3 Radiated Disturbance Immunity
EN 55024:1998 / IEC 61000-4-3:2002
4 Harmonic Current Emissions
EN 61000-3-2:2001 / EN 61000-3-2:2001
5 Voltage Fluctuations/Flicker
EN 61000-3-3 A1:2001 / EN 61000-3-3 A1:2001
6 Voltage Dips and Sags Immunity
EN 55024:1998 / IEC 61000-4-11:2001
7 Electrical Fast Transient/Bursts Immunity
EN 55024:1998 / IEC 61000-4-4:2001
8 Conducted Disturbance Immunity
EN 55024:1998 / EN 61000-4-6 A1:2001
9 Electrostatic Discharge Immunity
EN 55024:1998 / IEC 61000-4-2:2001
10 Surge Immunity
EN 55024:1998 / IEC 61000-4-5:2001