ELECTRIC BICYCLE METER — LCD3 Product User Manual
- 27 -
After finishing C4 parameter setting, hold
button (SW) shortly to save the
current set values and enter C5 parameter setting interface.
○
C5
Controller Maximum Current Adjustment Mode
Enter C5 parameter setting interface after C4 parameter setting is finished, C5
parameter column flashes.
C5 parameter setting interface
C5 is controller maximum operating current adjustment mode (tiny-adjustment of
limit current value). The default value is 10, setting range is 0-10, hold
button (
UP
)
or
button
(DOWN)
shortly for selection.
C5 parameter definition table
:
C5 value
Maximum current value(A)
00
Undefined
01
Undefined
02
Undefined
03
Maximum current value
÷
2.00
04
Maximum current value
÷
1.50
05
Maximum current value
÷
1.33
06
Maximum current value
÷
1.25
07
Maximum current value
÷
1.20
08
Maximum current value
÷
1.15
09
Maximum current value
÷
1.10
10
Maximum current value
When C5 setting is 10, maximum current value is controller maximum operating
www.HalloMotor.com