5
OK
+
=
+
=
75.0047.01 LZR-WIDESCAN Mechanical Installation 20210726
Page 9 of 12
4. ADJUST THE LATERAL ANGLE
Using the following instructions, launch the Position Wizard to position the detection field correctly in front of the door. This feature
is required for any off-center mounting positions, but also useful for a center-mount to verify the centered position.
POSITION THE DETECTION FIELD (cont.)
c. While observing the LCD screen, rotate the sensor until the arrow and triangle are aligned.
NOTE: Visible spots may no longer be centered during this step.
b. While observing the LCD screen, rotate the sensor to align the center of the red spots with the center of the door, then press
the OK button.
a. Press and hold the OK button. The LCD will display the following image.
HO
LD
d. Check that you are not interfering with the pattern and that the red spots are on the floor with no interference.
Press the OK button to set the angle.
If using the app, verify angle setting.
e. Lock the sensor position by tightening the angle lock screw.
Small movements can
make big changes!
Rotate sensor slowly
and stand back between
adjustments to allow
sensor to see the ground.