SENSITRON
A Halma Company
MTEX4899
SMART S-MS MED
Manuale (IT)
P. 23/36
2. Certifications
SMART S-MS MED series gas detectors meet the essential health and safety
requirements in accordance with the ATEX Directive 2014/34/EU.
The gas detectors of the ST series have been designed for use in potentially
explosive atmospheres due to the presence of gas, vapour, mist and dust,
classified as zone 1 or zone 2 (or zone 21 or 22 when the dust cover is applied)
according to EN 60079-10-1 and EN 60079-10-2 classification.
In particular they have undergone a series of performance tests and are
constructed according to the CESI 02 ATEX 084X certificate in compliance with
EN 60079-29-1:2016, suitable for use as safety devices.
SMART S-MS MED comply with the essential health and safety requirements of
MED directive 2014/90/UE.
2.1 MARKING
The detectors are equipped with an instrument label with one of the following
markings indicating the explosion protection mode:
0722 II 2G Ex db IIC T* Gb
Or, when equipped with dust adapter:
0722 II 2GD Ex db IIC T* Gb
Ex tb IIIC T5 T***°C Db
IP65
0525/2021
Table 2
The data present on the marking label is explained below
Sensitron S.r.l.
Viale della Repubblica 48, 20010
Cornaredo MI Italia
Name and address of the manufacturer of the electrical device
Conformity marking for the applicable European directives
ST/…/ ./..
Identification
s/n
Year
Serial number and year of production
0722
Number of the Notified Body that audits the production system
Conformity marking to the ATEX Directive 2014/34/EU and to the related
technical regulations
CESI 02 ATEX 084X
CESI: name of the laboratory that released the UE type certificate
yy: year of issuing of the certificate
nnn: number of the certificate
II
Electrical equipment for surface plants (not allowed in mines)
2
Category of the electrical devices for use in areas classified as zone 1 and zone 2
(by redundancy)
G
Electrical equipment for atmospheres with the presence of flammable gas
GD
Electrical equipment for atmospheres with the presence of flammable gas and
combustible dust
Ex db
Explosion proof protection mode based on EN 60079-1