background image

Page 1

OPERATING MANUAL

WATER 

SOFTENER

 

with CK10 Metered Valve

Summary of Contents for CK10

Page 1: ...Page 1 OPERATING MANUAL WATER SOFTENER with CK10 Metered Valve...

Page 2: ...oftening Ion Exchange 3 Valve Specifications 4 Model Specifications 5 Assembly 6 Control Valve Function 7 Regeneration Steps and Purpose 7 Exchange Capacity Data 7 Installation 8 Start Up 12 General O...

Page 3: ...because the min erals are ionic in nature often called ionized impurities which means they have an electrical charge The ion exchange process is based on the fact that like charges repel one another a...

Page 4: ...kPa drop Regenerant Refill Rate 5 gpm 1 9 lpm Inlet Outlet Fitting Options a 1 NPT elbow which has a unique drill out feature to allow a 1 4 NPT connec tions to the inlet and or outlet b 3 4 1 PVC so...

Page 5: ...only The control valve re members all settings for two hours if the power goes out After two hours the only item that needs to be reset is the time of day all other values are permanently stored in th...

Page 6: ...nd appliances in home if possible outside faucets should be separate so not to waste soft water Select location that is easily accessible to 110vac power A 15 foot power cord is provided You will also...

Page 7: ...alling sweat copper follow state and federal codes by using a lead free solder and flux Use a joint compound to seal threaded pipe Some homes use the cold water pipes for an electrical ground metal on...

Page 8: ...and o ring Heat from soldering or solvent cements may damage the nut split ring and o ring Make sure solder joints are cool before assemble is started Slip the nut onto the fitting first then the spli...

Page 9: ...he nut on to the 3 4 drain line fitting The nut is only designed for use with flexible poly tube Use other nuts if at taching different materials Run line to a drain Making sure you have 1 1 2 airgap...

Page 10: ...ogramming needed at startup is to set the hardness and time of day To set the time of day press the Set Clock button then use the up or down arrow buttons to set the hour pay attention to the AM PM in...

Page 11: ...play Cleaning Iron Out of the Water Softening System The system is designed to remove minerals like calcium and magnesium from household water Periodic resin bed clean ing is recommended if your water...

Page 12: ...e Setting Options Table for more detail Press NEXT to go to Step 7S Press REGEN to return to previous step STEP 7S Set Refill option using Down or Up buttons PoST to refill the brine tank after the fi...

Page 13: ...n occurs immediately when volume capacity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur when volume capacity reaches 0 AUTO NORMAL on 0 oFF Reserv...

Page 14: ...w REGEN on 0 GAL if on 0 is selected in Step 9S or Step 7F Press NEXT to go to step 5I Press REGEN to return to previous step STEP 5I Next Regeneration Time minutes Set the minutes of day for regenera...

Page 15: ...ll begin to regenerate immediately The request cannot be cancelled Note For softeners if brine tank does not contain salt fill with salt and wait at least two hours before regenerating Set Time of Day...

Page 16: ...the last 63 days This display will show dashes if a water meter is not installed Press the NEXT button at any time to go to Step 6D Press REGEN to return to previous step STEP 6D Flow rate current Tur...

Page 17: ...step STEP 4VH Gallons total used since start up This display shows the total gallons treated since startup This display will equal zero if a water meter is not installed Press the NEXT button to go t...

Page 18: ...nese and chlorine levels greater than 1 ppm are expressly not covered by the 5 year warranty Labor is not included Warranty is limited to repair of replacement of defective part manufacturer s choice...

Page 19: ...iagnostic Simultaneously Press UP DOWN then release 1 Number of Days Since Last Regen Press Next 2 Number of Gallons Since Last Regen Press Next 3 Reserve Capacity Gallons Used Last 7 Days Press Next...

Reviews: