SYSTEM SPECIFICA

TIONS / W

ARNING / NOTES

HALO WATER SYSTEMS, LLC COPYRIGHT  2020 ALL RIGHTS RESERVED

Equipment Specifications

HALO Water Systems, 

H2 ZERO

®

 systems are completely 

loaded with media and ready to use. 

ZERO

 drain 

necessary, 

ZERO

 maintenance & 

ZERO

 electricity required

H2 ZERO

®

 media needs to be protected from excess levels 

of certain metals that can easily coat the active surface, 

reducing its effectiveness over time.  If the water supply is 

from a municipal supply or a private well, confirm that the 

levels of iron (Fe) and manganese (Mn) are less than 0.3 

mg/L and 0.05 mg/L, respectively.

Please have a comprehensive well water sample taken be-

fore installation to ensure proper functionality. DO NOT install 

this system on a well without proper testing and recommen-

dations from the manufacturer. This will void the warranty

WARNING

New Copper lines need to be passivated for a minimum of 

4 weeks before placing scale media into service. System 

can run filtration only for 4 weeks before putting scale media 

into service. For applications with copper concentration 

greater than 1.3 ppm, please consult HALO Water Systems. 

To further minimize any problem with excess copper, avoid 

applying excessive flux on the inner surfaces of the pipe 

and use a low corrosivity water soluble flux listed under the 

ASTM B813 standard. This can be avoided by use of non-

copper pipes.

No hydrogen sulfide can be present.  Media will turn gray 

and unit will no longer be effective.

 

System can run filtration only for 4 weeks before putting 

scale media into service.

NOTICE: H2 ZERO

® 

media does not reduce silica scaling. 

While silica tends to have a less significant effect on scale 

formation than other minerals, it can act as a binder that 

makes water spots and scale residue outside the plumbing 

system difficult to remove. This 20 ppm limitation is for 

aesthetic purposes.

Water known to have heavy loads of dirt and debris may 

require pre-filtration (Sediment Filter SC510)  prior to 

H2 ZERO

®

.

Pressure ............

15 psi to 90 (1.03 bar to 6.2 bar)

Temp. ............................................

40º F to 100º F 

Free Chlorine ............................................

<2ppm

pH ...............................................................

6.5-8.5

Iron (maximum) ........................................

0.3 ppm

Manganese (maximum) .........................

0.05 ppm

Copper ......................................................

1.3 ppm

Maximum Hardness

..................................35GPG

Feed Water Chemistry Requirements