SYSTEM SPECIFICA
TIONS / W
ARNING / NOTES
HALO WATER SYSTEMS, LLC COPYRIGHT 2020 ALL RIGHTS RESERVED
Equipment Specifications
HALO Water Systems,
H2 ZERO
®
systems are completely
loaded with media and ready to use.
ZERO
drain
necessary,
ZERO
maintenance &
ZERO
electricity required
H2 ZERO
®
media needs to be protected from excess levels
of certain metals that can easily coat the active surface,
reducing its effectiveness over time. If the water supply is
from a municipal supply or a private well, confirm that the
levels of iron (Fe) and manganese (Mn) are less than 0.3
mg/L and 0.05 mg/L, respectively.
Please have a comprehensive well water sample taken be-
fore installation to ensure proper functionality. DO NOT install
this system on a well without proper testing and recommen-
dations from the manufacturer. This will void the warranty
WARNING
New Copper lines need to be passivated for a minimum of
4 weeks before placing scale media into service. System
can run filtration only for 4 weeks before putting scale media
into service. For applications with copper concentration
greater than 1.3 ppm, please consult HALO Water Systems.
To further minimize any problem with excess copper, avoid
applying excessive flux on the inner surfaces of the pipe
and use a low corrosivity water soluble flux listed under the
ASTM B813 standard. This can be avoided by use of non-
copper pipes.
No hydrogen sulfide can be present. Media will turn gray
and unit will no longer be effective.
System can run filtration only for 4 weeks before putting
scale media into service.
NOTICE: H2 ZERO
®
media does not reduce silica scaling.
While silica tends to have a less significant effect on scale
formation than other minerals, it can act as a binder that
makes water spots and scale residue outside the plumbing
system difficult to remove. This 20 ppm limitation is for
aesthetic purposes.
Water known to have heavy loads of dirt and debris may
require pre-filtration (Sediment Filter SC510) prior to
H2 ZERO
®
.
Pressure ............
15 psi to 90 (1.03 bar to 6.2 bar)
Temp. ............................................
40º F to 100º F
Free Chlorine ............................................
<2ppm
pH ...............................................................
6.5-8.5
Iron (maximum) ........................................
0.3 ppm
Manganese (maximum) .........................
0.05 ppm
Copper ......................................................
1.3 ppm
Maximum Hardness
..................................35GPG
Feed Water Chemistry Requirements