Page 11
97631C (REV. D - 06/17)
STEP 3
Reconnect Internal Plumbing
• Connect water inlet line to chiller inlet.
• Connect chiller outlet to tee (Item 4).
• Cut a 12 inch long piece of tube (Item 1).
Install into the chiller water outlet. Connect end
to tee (Item 4).
• Connect tee to regulator and glass filler supply tube.
• Cut a 6 inch long piece of tube (Item 1).
• Connect one end of tube to tee (Item 4) and
other end to water regulator inlet (D).
• Cut another 12 inch long piece of tube (Item 1).
• Connect tube to tee (Item 4) and to Glass Filler
Nipple (Item 2).
• Connect bubbler tube to regulator.
• Use tank to bubbler tube, removed in Step 2, cut
length of tube to 10 inches and connect to
regulator outlet.
SCREWS
STEP 4
Reassemble Unit
• Using one gasket (Item 5) below the basin and
one gasket (Item 5) above the basin assemble
the glass filler (Item 6, not supplied) to the basin
with glass filler nipple (Item 2).
• Connect bubbler tube to glass filler nipple in basin.
•
Flush components and leak check
.
• Assemble basin to the unit. Reattach with screws
removed in Step 2.
• Turn on water supply and reconnect electrical supply.
Run water through the bubbler by depressing pushbar
and through glass filler. Check all connections for leaks.
Reinstall lower panel with screws removed in step 1.
3.75
3.75
Step 2
Step 3
STEP 2
Remove Cooler Basin
• Remove basin screws (2 each side, 4 total).
• If cooler is installed remove strainer and drain plug or disconnect unit from trap.
• Lift front of basin and disconnect bubbler tube from bubbler.
Refer to details "Operation of Quick Connect Fittings" for
removing tubes.
• Remove cooler basin.
Remove glass filler plug from basin
If the hole HAS NOT been prepunched, then drill or punch a 11/16” (.687”) diameter hole in the cooler basin
where shown or desired. Note: Tube length may vary depending upon glass filler location.
Cut and Remove Internal Plumbing
• Disconnect bubbler tube (A) at chilled tank water outlet.Save the tube. This will be used in step 4.
• Disconnect supply tubes at locations (B) and (C).
• Remove and discard bent tubes from water regulator (D).
• Refer to details “Operation of Quick Connect Fittings” for removing tubes
.