Page 4
97631C (REV. D - 06/17)
Overview
The following illustration shows the tube routing before and after the installation of the Glass Filler Kit.
Before (Non-Pressurized Tank)
After (Pressurized Tank)
The water storage tank must be converted to a pressurized tank for the glass filler to operate properly. The
tank is non-pressurized in a standard unit. The following steps detail how the water flow tubing is re-routed to
create a pressurized tank and provide a supply line to the glass filler.
A
Note: Item numbers in the following steps refer to items in Parts List on page 1.
Step 1 & 2
SCWT Model
STEP 1
Remove Cooler Front Panel
• Remove front panel.
• Remove screws on kick plate and front panel (A).
• Remove front panel.
• Disconnect cooler from electrical supply.
• Turn off water supply to unit.
• Remove bubbler (B).
• Remove pushbutton (C).
• If cooler is installed, remove strainer and drain plug (D)
or disconnect unit from trap.
• Remove 4 screws and take off basin.
STEP 2
•
Drill or punch an 11/16” (.687”) diameter hole in the center of
the raised circular pad at the right rear corner of the basin.
C
B
D