background image

Page 6

98767C  (Rev. A - 6/11)

HVRGRN8WS*1B   HVRGRN8BLWS*1B

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the
    unit will need to be shut down and restarted. The chiller
    (if present) does not need to be shut down and restarted.
2) The units lower panel must be open to access the power
    cord and wall outlet.
3) Shut down the unit by unplugging the power cord from the
    wall outlet.
4)  Restart the unit by plugging the power cord back into the
    wall outlet.
5) Upon start up the bottle count display will show the
    software designation of BF6, BF7, BF8 or BF9.
6) Reference the BF6-BF7-BF8 or BF9 instructions for setting
     the control board.

ACCESSING THE PROGRAMING BUTTON

1)   To access the program button 

remove the top cover of

    the bottle filler. Remove the  two (2) screws holding top
    cover to bottle filler with a 5/32” allen wrench . Remove
    top cover. Do not discard mounting screws, they will be
    needed to reinstall the top cover

 

after programming

    operations are completed. The programming button is
      

located at the top right side of the unit on the control board.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.
2) Depress the program button for approximately 2 seconds
    until the display changes then release. The display will
    change and scroll through two messages:
      

 “RST BCNT” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu
    If the program button is not pushed again the display
    will scroll through the two messages above for
    three cycles and then default back to bottle count and
     be back in run mode.
3) When the display changes to “RST FLTR”, depress
    the button again. The display will change to show
     “FLT =”. Depress the button again and the display
    will show “FLTR =0”
4) The Green LED should be illuminated indicating that

    the visual filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds
    until the display changes then release. The display will
    change and scroll through two messages:
       “RST FLTR” – Reset Filter Status LED
     “SETTINGS” – System Settings Sub Menu
    If the program button is not pushed again the display
    will scroll through the two messages above for
    three cycles and then default back to bottle count
     and be back in run mode.
2) When the display changes to “SETTINGS”, depress
    the button again. The display will change to show
     “RNG SET“-  Range set for IR sensor.
      “UNIT TYP“ - Type of unit (REFRIG or NON-REFRIG)
     “RST BCNT“ - Reset bottle count
3)  When display shows “RNG SET” push program
    button once the display will show current value
     (can be 1 – 10) i.e. “RNG = 3”.
4) Once display shows current value push the
    program button to scroll through value of 1 – 10.
    Select the desired range setting.
5) Once range is selected allow approximately
    4 seconds to pass and then the display will go
     back to bottle counter and be in run mode.
6)  Test bottle filler by placing bottle or hand in front

    of sensor to make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds
    until the display changes then release. The display will
    change and scroll through two messages:
      “RST FLTR” – Reset Filter Status LED
     “SETTINGS” – System Settings Sub Menu
    If the program button is not pushed again the display
    will scroll through the two messages above for
    three cycles and then default back to bottle count
      and be back in run mode.
2)  When the display changes to “SETTINGS”, depress
    the button again. The display will change to show
     “RNG SET“-  Range set for IR sensor.
       “UNIT TYP“ - Type of unit (REFRIG or NON-REFRIG)
      “RST BCNT“ - Reset bottle count
3)  When display shows “UNIT TYP” push program
    button once the display will show current value
       Can be REFRIG or NON-REFRIG
4) Push button once to change value. Once value is
      selected the display will show the new value.
       (Can be REFRIG or NON-REFRIG)
     “REFRIG“ - stands for refrigerated product. In this
     setting the flow rate is estimated at 1.0 gallon per minute.
     “NON-REFRIG“ - stands for non-refrigerated product.
    In this setting the  flow rate is estimated
      at 1.5 gallons per minute.
      Both “REFRIG“ and “NON-REFRIG“ simulated
       1 bottle equal to 20 oz.
5)  Allow approximately 4 seconds to pass and the display
     will return to bottle counter and be in run mode.

     RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds
    until the display changes then release. The display will
    change and scroll through two messages:
      “RST FLTR” – Reset Filter Status LED
      “SETTINGS” – System Settings Sub Menu
    If the program button is not pushed again the display
    will scroll through the two messages above for
    three cycles and then default back to bottle count
     and be back in run mode.
2)  When the display changes to “SETTINGS”, depress
    the button again. The display will change to show
     “RNG SET“-  Range set for IR sensor.
       “UNIT TYP“ - Type of unit (REFRIG or NON-REFRIG)
      “RST BCNT“ - Reset bottle count
    If the button is not pushed again the display will scroll
    through the three messages above for three cycles and
     return to run mode.
3)  When display shows “RST BCNT” push program button
    once the display will show current value i.e. “000033183”.
4) Once display shows current value push the program
    button once more to reset back to 0. The display will
    show BTLCT = 0 for approximately 2 seconds and
    then return to run mode showing 00000000 bottles.
5)  Testing the bottle counter:
     REFRIG units: Place bottle or hand in front of sensor for
    9.4 seconds to see bottle counter count 00000001,
     (This is based on filling a 20 oz. bottle).
     NON-REFRIG units: Place bottle or hand in front of sensor for
    6.25 seconds to see bottle counter count 00000001,
     (This is based on filling a 20 oz. bottle).

BF9 PROGRAM

SETTING THE CONTROL BOARD

Summary of Contents for GreenSpec HTHB-HVRGRN

Page 1: ...UIPMENT SUCHAS TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK INTOAFOU...

Page 2: ...11 16 18mm 2 7 16 63mm 3 1 2 89mm 4 1 2 114mm 5 127mm 9 15 16 252mm A D B E E F 18 3 8 467mm 21 3 8 543mm 25 635mm 30 15 16 786mm 51 9 16 1310mm Single Rough In Fig 1 HTHB HVRGRN REDUCE HEIGHT BY 3 FO...

Page 3: ...4 1 2 114mm 3 1 2 89mm 6 1 4 159mm FINISHED FLOOR 13 13 16 351mm 18 3 4 477mm 20 1 8 511mm 25 1 8 638mm 8 203mm 6 3 4 171mm 12 5 16 313mm 6 1 2 165mm 27 686mm 31 13 16 809mm RIM HEIGHT 32 15 16 837mm...

Page 4: ...mounting screws from step 1 above Caution do not over tighten screws 11 For Single Model Installations Install remaining tube insulation to the water line from bottle filler connect Bottle Filler wat...

Page 5: ...be illuminated indicating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display changes then release T...

Page 6: ...allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dis...

Page 7: ...C 98544C 98545C 98546C 98666C 98667C 98549C 98668C 98552C Kit Electrical Package Kit IR Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Top Cover Replacement Kit Drain Mat Cover Repl...

Reviews: