VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will

need to be shut down and restarted. The chiller (if present) does

not need to be shut down and restarted.

2) The units lower panel must be open to access the power cord and

    wall outlet.

3) Shut down the unit by unplugging the power cord from the wall

outlet.

4)  Restart the unit by plugging the power cord back into the wall

outlet.

5) Upon start up, the bottle count display will show the software

designation of BF11.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button remove the top cover of the bottle-

    filler. Remove the two (2) screws holding top cover to bottle-

    filler with a 5/32” allen wrench.  Remove top cover. Do not discard

    mounting screws, they will be needed to reinstall the top cove

 

after 

    programming operations are completed. The programming button 

    is located at the top right side of the unit on the control board.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds until

the display changes then release. The display will change and

scroll through two messages:

  “RST FLTR” – Reset Filter Monitor

“SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll

through the two messages above for three cycles and then default

back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button

again. The display will change to show “FLTR =”. Depress the

button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual

filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds until

the display changes then release. The display will change and

scroll through two messages:

  “RST FLTR” – Reset Filter Status LED

“SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll

through the two messages above for three cycles and then default

back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button

again. The display will change to show

“RNG SET” -  Range set for IR sensor.

“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

“FLT SIZE” - Select filter capacity

“RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program button once the

display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to

scroll through value of 1 – 10. Select the desired range setting.

5) Once range is selected allow approximately 4 seconds to pass and

then the display will go back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front of sensor to

make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

display changes then release. The display will change and scroll

through two messages:

       “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

Continued from below:

2)  When the display changes to “SETTINGS”, depress the button again.

The display will change to show

“RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

3)  When display shows “UNIT TYPE” push program button once the

display will show current value.  Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is    selected the display

will show the new value.  (Can be REFRIG or NON-RFRG)

 

“REFRIG“ - stands for refrigerated product. In this setting the flow rate is

estimated at 1.0 gallon per minute.

 “NON-RFRG“ - stands for non-refrigerated product. In this setting the

flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ and

“NON-RFRG“ simulate   1 bottle equal to 20 oz.

5)  Allow approximately 4 seconds to pass and the display will return to

bottle counter and be in run mode.

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

display changes then release. The display will change and scroll

through two messages:

 “RST FLTR” – Reset Filter Status LED

 “SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll through

the two messages above for three cycles and then default back to bottle

count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button again.

The display will change to show:

“RNG SET”-  Range set for IR sensor.

“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

 

“FLT SIZE” - Select filter capacity

“RST BCNT” - Reset bottle count

If the button is not pushed again the display will scroll through the four

messages above for three cycles and return to run mode.

3)  When display shows “RST BCNT” push program button once the

display will show current value e.g. “00033183”.

4) Once display shows current value push the program button once more

to reset back to 0. The display will show BTLCT = 0 for approximately 2

seconds and then return to run mode showing 00000000 bottles.

5)  Testing the bottle counter:

REFRIG units: Place bottle or hand in front of sensor for 9.4 seconds to

see bottle counter count 00000001,

(This is based on filling a 20 oz. bottle).

NON-RFRG units: Place bottle or hand in front of sensor for 6.25

seconds to see bottle counter count 00000001,

(This is based on filling a 20 oz. bottle).

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

display changes then release. The display will change and scroll through

two messages:

 “RST FLTR” – Reset Filter Status LED

 “SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll through

the two messages above for three cycles and then default back to bottle

count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button again.

The display will change to show:

“RNG SET“-  Range set for IR sensor.

“UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

 

“FLT SIZE” - Select filter capacity

“RST BCNT“ - Reset bottle count

If the button is not pushed again the display will scroll through the four

messages above for three cycles and return to run mode.

3)  When display shows “FLT SIZE” push program button once. The display

will show current value. Can be 3000GAL or 6000GAL.

4) Push program button again to display the desired “FLT SIZE”.

5) Allow approximately 4 seconds to pass and the display will return to

bottle counter and be in run mode.

BF11 - BF12 PROGRAM

SETTING THE CONTROL BOARD

Buy at

| 855-558-9600 | BottleFillingStations.com

Summary of Contents for HTHB-HAC

Page 1: ...AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN C...

Page 2: ...oth front panels WARNING Before proceeding Disconnect electrical power supplying the water cooler Switch circuit breaker OFF or remove fuse Unplug water cooler power cord from electrical outlet Shut o...

Page 3: ...emove drain hardware from original basin Remove the protective covering from the basin Reinstall the drain elbow drain plug and strainer plate on to the new basin Attach the new drain hardware onto th...

Page 4: ...e Screw the locknut hand tight to seal Attach port fittings onto Filter Head 2 Attach Filter head assembly If not already preassembled Attach Filter head assembly to filter mounting bracket with four...

Page 5: ...ter inlet using the supplied 3 8 3 8 union connector Discard in line strainer Single Level Models Two Level Models Single Level Models Mount on inside of left panel butted up against top lip NOTE The...

Page 6: ...1 4 poly tube into the Regulator Outlet unmarked Opposite end of 1 4 poly tube will be inserted later into the Bubbler RE PLUMBING SINGLE STATION WATER CIRCUITS NON FILTER CAUTION This procedure MUST...

Page 7: ...bing 6 from the Evaporator Outlet and insert the 1 4 Tee fitting between the two pieces Connect Bottle Filler supply line to Tee fitting Remove 1 4 poly tubing from Bubbler 3 Re route water supply to...

Page 8: ...left hand unit cut the Evaporator Outlet 1 4 poly tubing 5 from the access opening between the units and insert the 1 4 Tee fitting between the two pieces Fig 4 HAC TWO LEVEL HYDROBOOST PLUMBING STAN...

Page 9: ...Filter outlet using 1 4 poly tubing to the Evaporator 1 4 copper inlet using the supplied 1 4 quick connect fitting 2 Add water supply to Bottle Filler In the left hand unit cut the Evaporator outlet...

Page 10: ...tion Basin Assembly Basin with Drain and Bubbler hardware back onto the cooler Reattach drain line to P trap and tighten 3 Fasten Basin Assembly in place Insert and retighten the 8 screws four per sid...

Page 11: ...Page 11 1000001732 Rev D 06 16 HAC HB 1B HAC HB NF 1B Fig 6 Fig 7 Buy at 855 558 9600 BottleFillingStations com BOTTLE FILLER GASKET...

Page 12: ...re s and waterline through hole on top of water cooler place Bottle Filler on the three 3 angled tabs protruding from the wall See Fig 10 mounting plate installed on wall Make sure round boss in gaske...

Page 13: ...Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE S...

Page 14: ...8 Elbow Fitting Assy Filter Bracket includes Fltr Head Mtg Bkt John Guest Ftgs Screws 1 2 3 55898C 98926C 0000000746 DESCRIPTION PART NO FILTER PARTS LIST See Fig 12 Ens filtre 3000 Gallon Raccord T...

Page 15: ...ilter Mounting Cover SS Kit Retro Filter Mounting Kit Basin Kit Bottle Filler Drain Kit Tower Gasket Brkt Screws Washers Kit Drain Replacement REPLACEMENT PART KITS PART NO PRINTED IN U S A IMPRESO EN...

Reviews: