Page 2
HVR8BL(R)*1D HVR8BLWF*1D
98953C (Rev. A - 3/12)
OR
IF
IC
E
HE
IG
HT
AL
T
U
R
A
D
E
L
O
R
IF
IC
IO
H
AU
T
E
U
R DE
L'
O
R
IF
IC
E
OR
IF
IC
E
HE
IG
HT
AL
T
U
R
A
D
E
L
O
R
IF
IC
IO
HA
U
T
E
U
R DE
L'
O
R
IF
IC
E
FI
N
ISH
E
D
FL
O
O
R
PI
S
O
AC
AB
ADO
PL
AN
C
H
ER F
IN
I
RI
M
HE
IG
HT
AL
T
U
R
A
D
E
L
A
C
O
RO
NA
H
A
U
T
E
U
R DU
BO
R
D
C
D
A
B
F
25
1
/8
"
63
8
m
m
20
1
/8
"
51
1m
m
18
3
/4
"
47
6mm
13
7/
8"
35
2m
m
C L
C L
4 1
/2"
11
4
m
m
3 1
/2
"
89m
m
6 1
/4
"
15
8
m
m
1 1
/2
"
38
m
m
10
"
25
4mm
5" 12
7
m
m
2 7
/1
6
"
63
m
m
20
3/
8
"
51
8
m
m
37
1
/2
"
95
2m
m
E
E
F
6 1
/2"
16
6
m
m
5
/1
6
" (8
m
m
) D
IA
. (1
0
H
O
L
E
S)
8
mm (
10 A
G
UJ
E
R
O
U
S
)
8m
m
(1
0
T
R
O
U
S
)
18
1/
16
"
45
9m
m
5 3/4
"
14
6
m
m
1 3
/8
"
35
m
m
5 3/
4"
14
6
m
m
1 3
/8
"
35
m
m
1 3
/8
"
35
m
m
1 3
/8
"
35
mm
12
5
/1
6
"
31
2
m
m
4 1
/8
"
10
5
m
m
8" 20
3mm
18
5
/8
"
47
4m
m
27
"
68
6mm
3
1 7/
8"
81
0
m
m
32
1
5
/1
6
"
83
7
m
m
39
1
/2
"
10
0
3
m
m
2 5
/8
"
67
m
m
HA
N
G
ER
B
R
ACKET
F
IJ
A
DO
R D
E
SU
S
PENS
IO
N
S
U
PP
O
R
T
D
E
SU
S
PENS
IO
N
*
5 3/
4
"
14
6
m
m
5 3/
4"
14
6
m
m
6 3/
4"
17
3
m
m
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76
m
m
) MAXIMUM
OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OT
ROS) 3 en. (76 Mm) el MAXIMO
FUERA DE PARED
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU
RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR L
ES AUTRES) 3 dans. (76 mm) le MAXIMUM
HORS DU MUR
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/2” DE DIÁMETRO.
El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2" DE SORTIE D’EAU.
STUB 2 HORS DU MUR
C = 1-1/2 TRAP NOT FURNISHED
PURGADOR DE 1-1/2 NO PROPORCIONADO
SIPHON 1-1/2 NON FOURNI
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm
) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6" (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUE
BLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6" (152
mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
FIG. 2
* * *
ADA REQUIREMENT
REQUISITO DE A.D.A.
EXIGENCE ADA
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
HVR8BL