HTHBHVR8 Bottle Fillers are among the easiest to install on the market today. To 

insure you install these models easily and correctly,  PLEASE READ THESE SIM-

PLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR 

INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND

OTHER APPLICABLE CODES. After installation, leave these instructions with the 

Fountain for future reference.

IMPORTANT

THIS IS AN INDOOR APPLICATION ONLY.  

ALL SERVICE TO BE PERFORMED BY AN

 AUTHORIZED SERVICE PERSON.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER 

LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY 

FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREAT-

ING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT 

OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY 

DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISO-

LATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING 

STATION AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).

INSTALLER

TOOLS REQUIRED

BUT NOT PROVIDED:

SAFETY GLASSES

GLOVES

ELECTRIC DRILL

3/4” WRENCH OR CRECENT WRENCH

UTILITY KNIFE

TAPE MEASURE

PENCIL

CENTER PUNCH

1/2” SOCKET & RATCHET WRENCH

5/32” ALLEN WRENCH

Installation/Care/Use Manual

Summary of Contents for HydroBoost HTHBHVR8

Page 1: ...CAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBAC...

Page 2: ...1mm 48 1219mm O 5 16 8mm MOUNTING HOLES 3 PL 1 4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm Single Rough In Fig 1 HTHBHVR8 REDUCE HEIGHT BY 3...

Page 3: ...6 811mm RIM HEIGHT 8 203mm 18 1 16 459mm 7 178mm 7 178mm 1 1 4 32mm 1 1 4 32mm 16 5 16 414mm O 5 16 8mm HOLES 3 PL 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 2 470mm 3 1 2 89mm 4 1 2 114mm 6 1...

Page 4: ...ires from non refrigerated unit to the black wires on the refrigerated unit see step 4 7 For Single Model Installations Install remaining tube insulation to the water line from bottle filler connect B...

Page 5: ...ides of the Bottle Filler Remove the two 2 Pinned Torx Head Screws from the Top Cover remove the Top Cover The Bottle Filler may then be lifted up and off the Water Cooler The water line and Remote Re...

Page 6: ...n default back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of...

Page 7: ...See Fig 7 LISTA DE PIEZAS DEL FIL TRO Vea Fig 7 LISTE DES PI CES DU FIL TRE Voir Fig 7 PRINTED IN U S A FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW HALSEYTAYLOR COM PARA PIEZAS D...