Printed in the U.S.A.
Specifications and measu
r
ements a
r
e subject to change without notification.
Please visit halseytaylo
r
.com for most cur
r
ent version.
FILTER LOCATION
(OPTIONAL)
1/4" O.D. TUBE CONNECT
(CHILLER WATER OUTLET)
3/8" O.D. TUBE CONNECT
(CHILLER WATER INLET)
SHUT OFF VALVE BY OTHERS
BACK WALL LINE
FINISHED FLOOR
1-1/4" (32MM)
WASTE TUBE
FURNISHED
ELECTRICAL
INLET
FINISHED FLOOR
STANDARD HEIGHT
20 3/8"
( 518mm )
20 7/16"
( 519mm )
19 3/4"
( 502mm )
17 3/8"
( 441mm )
1 3/16"
( 30mm )
1 3/16"
( 30mm )
8 1/8"
( 206mm )
9 3/8"
( 238mm )
1 1/8"
( 29mm )
3"
( 79mm )
18 3/4"
( 476mm )
4"
( 102mm )
12" *
( 305mm )
MINIMUM
DEPTH
25 1/4"
( 641mm )
27"
( 681mm )
38 7/8"
( 987mm )
2 7/8"
( 73mm )
25 7/8"
( 657mm )
3 1/2"
( 89mm )
4 1/2"
( 116mm)
1 1/8"
( 29mm )
11"
( 279mm )
DOUBLE STUD OR 3" (76mm)
BETWEEN MOUNTING FRAMES
IF PLACED NEXT TO ANOTHER
FOUNTAIN OR WALL
* 7" minimum depth
for non-refrigerated models
FILTER LOCATION
(OPTIONAL)
1/4" O.D. TUBE CONNECT
(CHILLER WATER OUTLET)
3/8" O.D. TUBE CONNECT
(CHILLER WATER INLET)
SHUT OFF VALVE BY OTHERS
BACK WALL LINE
FINISHED FLOOR
1-1/4" (32MM)
WASTE TUBE
FURNISHED
ELECTRICAL
INLET
FINISHED FLOOR
ANDARD HEIGHT
20 3/8"
( 518mm )
20 7/16"
( 519mm )
19 3/4"
( 502mm )
17 3/8"
( 441mm )
1 3/16"
( 30mm )
1 3/16"
( 30mm )
8 1/8"
( 206mm )
9 3/8"
( 238mm )
1 1/8"
( 29mm )
3"
( 79mm )
18 3/4"
( 476mm )
4"
( 102mm )
12" *
( 305mm )
MINIMUM
DEPTH
25 1/4"
( 641mm )
27"
( 681mm )
38 7/8"
( 987mm )
2 7/8"
( 73mm )
25 7/8"
( 657mm )
3 1/2"
( 89mm )
4 1/2"
( 116mm)
1 1/8"
( 29mm )
11"
( 279mm )
DOUBLE STUD OR 3" (76mm)
BETWEEN MOUNTING FRAMES
IF PLACED NEXT TO ANOTHER
FOUNTAIN OR WALL
* 7" minimum depth
for non-refrigerated models
40"
1016
mm
4 1/2
114
mm
18 3/4"
476
mm
5 1/8"
130
mm
BACK OF WALL TO
BE 12" (305
mm
)
MIN DEPTH
8"
203
mm
TO FLOOR LINE
FLOOR LINE
WOOD OR STEEL
FRAME SHOWN
(NOT PROVIDED)
ELECTRICAL INLET
LOCATION ON CHILLER
1"
25
mm
CHILLER SHELF
P/N 27638C
HOOK RODS (2)
P/N 101567443730
SCREWS OR BOLTS
(NOT PROVIDED)
5/16" SCREWS OR BOLTS
(10 REQ'D-NOT PROVIDED)
FRAME
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
MFWS100
DOUBLE STUD OR 3 INCHES (76
mm
)
BETWEEN MOUNTING FRAMES
IF PLACED NEXT TO ANOTHER
FOUNTAIN OR WALL
Supply water - 105 psi maximum
Minimum 40 psi supply line p
r
essu
re r
equi
red
in special ci
r
cumstances when both sides of
bilevel a
r
e in use simultaneously to ensu
re
adequate st
r
eam height. Does not apply to
non-
r
efrigerated units
.
Hyd
r
oboost station equipped with electric
co
r
d and th
ree-pr
ong molded rubber plug for
use with 15-amp minimum
r
eceptacle.
For the cooling unit, a junction box for a (3)
wi
r
e , 10 amp branch ci
r
cuit is p
r
ovided.
Rated at 115 volt, 60 Hz, single phase.
MODEL HTHBWF-HRFER
OPERATING PRESSURES:
ELECTRICAL
SIDE VIEW
FRONT VIEW / WALL LAYOUT
HydroBoost In-Wall Bottle Filler
®
* Rated for Indoor Use Only