PAGE 5
SCWT14WQ*1K
98702C (Rev. D - 04/16)
ITEM NO. PART NO.
DESCRIPTION
15005C
51544C
101507531550
101453431640
102639931640
160270508640
28346C
26860C
26861C
26862C
35839C
36312C
35840C
35768C
75589C
192668451550
45696C
66581C
75561C
50986C
66798C
66811C
55880C
61314C
66203C
75494C
55996C
55913C
75588C
56159C
70682C
See Color Table
See Color Table
35843C
35844C
56092C
70683C
75583C
See Color Table
Nut-Regulator Retaining
Bubbler
Push Button Stem
Cap Push Button
Drain Plug
Strainer Plate
Basin
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Cold Control
Compressor Service Pak
Overload
Relay Cover
Gasket
Power Cord
Tailpipe Assy
Heat Exchanger
Elbow - 3/8"
Regulator Holder
Condenser Assy
Evaporator
Regulator Mounting Bracket
Regulator
Drier
Check Valve
Strainer
Adaptor-Drain W/O Holes
Nut - Slip Joint 1-1/4
Nipple - Bubbler
Tee - 1/4
Side Panel - Right
Side Panel - Left
Relay
Capacitor
Poly Tubing (Cut To Length)
Union - 1/4
Elbow - 5/16" x 1/4"
Front Panel
401536248410
401536242830
401536348410
401536342830
401507448410
401507442830
RIGHT PANEL
FRONT PANEL
LEFT PANEL
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers or
orders for repair parts MUST include Model No. and Serial No. of cooler,
name and part number of replacement part.
ITEMIZED PARTS LIST
1
2
3
4
5
6
7
8
9
10
11
*12
13
14
15
16
**17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
NS
NS
FIG. 6
CONDENSER WATER VALVE ADJUSTMENT
The condenser water valve is factory preset for a
condenser water outlet temperature of 95° to 105° F.
If actual temperature varies greatly from this, readjust water
flow rate at the valve using the following procedures.
1.
START UP COMPRESSOR
This can be accomplished by depressing the cooler
push button (See Fig. 1 - Item 4). Keep water
running during the entire readjustment procedure.
2.
ADJUSTMENT CONDENSER WATER VALVE
Adjust valve by rotating adjustment stem. Rotating stem
clockwise will increase water flow.
Counterclockwise rotation will decrease water flow.
Increasing water flow will result in a lower
condenser outlet temperature, while decreasing water
flow will result in a higher outlet temperature.
Proper adjustment is attained when condenser outlet
temperature is 95° to 105° F.
**Includes Items 15, 28 & 29
Platinum (PV)
Stnlss Stl (SS)
COLOR
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.