6. Preparation

6.1  General Information

1.  This Remote Chiller is designed for indoor use only 

and should not be installed outdoors or in a humid 

environment.

2. 

Use care when opening and removing the 

packaging to prevent damage to the product.
a.  Inspect the product for any shipping damage 

and report it immediately to the location of 

purchase. Installation of a damaged product will 

void the warranty. 

b. 

Confirm that all parts have been included for the 

proper installation of this product. Contact the 

location of purchase if damaged parts are found.

NOTICE

Make sure no electrical wiring, 

potable water inlet pipes, or 

drain water outlet pipes will be damaged during 

installation of the product. Damage to any of 

these items can cause electrical damage, fire, 

and/or water damage.

3. 

Shut off the water supply source and disconnect 

power to the electrical outlet being used to operate 

the product before starting installation.

NOTICE

Mounting hardware to be 

supplied by customer.

4.  It is important to ensure proper ventilation. 
5.  When mounting in an open area, to ensure proper 

ventilation, maintain a 4" (102mm) clearance from 

cabinet louvers on each side of chiller. When 

mounting unit in a cavity or behind a wall, maintain 

a minimum space of 4" (102mm) on each side, 4" 

(102mm) on the top and a depth of 12" (305mm).

6. 

Water inlet is 3/8” (10 mm) O.D. unplated tube.  

Contractor to supply connections as required.

7.  Connecting lines to be made of unplated copper. 

Thoroughly flush all lines to remove all foreign 

matter before connecting to chiller. If flushing does 

not remove all particles, a water strainer should be 

installed in supply line. This chiller is manufactured 

in such a manner that it does not in any way cause 

taste, odor, color or sediment problems.

8. 

Connect chiller to building supply with a shut-off 

valve and install

 the in-line strainer between the 

valve and chiller

.

9. 

Electrical: Make sure power supply is identical 

in voltage, cycle, and phase to that specified on 

chiller serial 

plate. Never wire the compressor 

directly to the power supply.

7. Installation: Electrical Connection

1. 

Turn off electrical supply to chiller circuit.

2.  Remove the front panel to gain access to electrical 

box using a 5/16" (7.9mm) socket wrench or a 

flathead screwdriver.

 

 

3.  Rotate the fan to ensure a proper clearance and 

free fan action.

4. 

Use 3/8” cable clamp connector or appropriate 

conduit connector with nut to connect the electrical 

wire to the unit.

 

 

5. 

Connect ground wire (A) to ground screw (provided).

 

 

A

Conduit 

Connector

Nut

Screw

Front Panel

Ground

Wire

Electrical

Box

Summary of Contents for SJ8

Page 1: ...SJ8Q_1P 630 574 8484 Halsey Taylor 2000000695 Rev A 07 22 Page 1 SJ8 Refrigeration Package INSTALLATION CARE AND USE MANUAL...

Page 2: ...ation Preparation Read Before Beginning Installation 7 4 Tools and Supplies 7 4 1 Tools Required 7 4 2 Installer Supplied Parts 7 4 3 Tools Items required but not provided 7 5 Ratings 7 5 1 SJ8 Series...

Page 3: ...llowed by a signal word such as WARNING or CAUTION 1 3 Definitions DANGER The signal word that indicates a hazard with a high level of risk which if not avoided will result in death or serious injury...

Page 4: ...ntenance make sure the unit is unplugged and circuit breakers are turned OFF Prior to installation test for live circuits or wiring inside the wall before cutting or drilling into the wall Failure to...

Page 5: ...Disclaimer The information contained in this Installation Use Care Manual is given free of charge It is based upon technical data which we believe to be reliable and is intended for use by persons ha...

Page 6: ...61mm 16 3 4 425mm 1 3 4 95mm REF C D 1 3 8 35mm 2 50mm A B 13 1 4 338mm 1 25mm LEGEND A 1 4 O D TUBE WATER OUTLET B 1 4 O D TUBE WATER INLET C TEMPERATURE ADJUSTMENT D ELECTRICAL USES HFC 134A REFRIGE...

Page 7: ...ughly flush all water lines and fittings of all foreign matter before connecting to chiller If inlet pressure is above 100 psig 0 69 MPa a pressure regulator must be installed in water supply line Any...

Page 8: ...ch side of chiller When mounting unit in a cavity or behind a wall maintain a minimum space of 4 102mm on each side 4 102mm on the top and a depth of 12 305mm 6 Water inlet is 3 8 10 mm O D unplated t...

Page 9: ...will require disconnecting electrical supply removal of panels etc and reassembly and return to service practices 9 2 1 Condenser Fan Motor Visually check and confirm the condenser fan turns freely If...

Page 10: ...USHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE Operation of Quick Connect Fittings Fig 3 A C B D A Plug with 7 8 22 2mm Hex B O ring C Screen D Strainer Body with 1 25 4mm Hex Fig 1 NOTE W...

Page 11: ...nt part Kit Evap Replace Assy Cabinet Kit Condenser Drier Bracket Fan Mounting Kit Heat Exchanger Drier Drier Kit Cold Control Screws Panel Front Kit Compressor Mtg Hdwe Bumper Baseplate Panel Rear In...

Reviews: