Page 8
Halsey Taylor
(630) 574-8484
2000000695 (Rev. A - 07/22)
SJ8Q_1P
6. Preparation
6.1 General Information
1. This Remote Chiller is designed for indoor use only
and should not be installed outdoors or in a humid
environment.
2.
Use care when opening and removing the
packaging to prevent damage to the product.
a. Inspect the product for any shipping damage
and report it immediately to the location of
purchase. Installation of a damaged product will
void the warranty.
b.
Confirm that all parts have been included for the
proper installation of this product. Contact the
location of purchase if damaged parts are found.
NOTICE
Make sure no electrical wiring,
potable water inlet pipes, or
drain water outlet pipes will be damaged during
installation of the product. Damage to any of
these items can cause electrical damage, fire,
and/or water damage.
3.
Shut off the water supply source and disconnect
power to the electrical outlet being used to operate
the product before starting installation.
NOTICE
Mounting hardware to be
supplied by customer.
4. It is important to ensure proper ventilation.
5. When mounting in an open area, to ensure proper
ventilation, maintain a 4" (102mm) clearance from
cabinet louvers on each side of chiller. When
mounting unit in a cavity or behind a wall, maintain
a minimum space of 4" (102mm) on each side, 4"
(102mm) on the top and a depth of 12" (305mm).
6.
Water inlet is 3/8” (10 mm) O.D. unplated tube.
Contractor to supply connections as required.
7. Connecting lines to be made of unplated copper.
Thoroughly flush all lines to remove all foreign
matter before connecting to chiller. If flushing does
not remove all particles, a water strainer should be
installed in supply line. This chiller is manufactured
in such a manner that it does not in any way cause
taste, odor, color or sediment problems.
8.
Connect chiller to building supply with a shut-off
valve and install
the in-line strainer between the
valve and chiller
.
9.
Electrical: Make sure power supply is identical
in voltage, cycle, and phase to that specified on
chiller serial
plate. Never wire the compressor
directly to the power supply.
7. Installation: Electrical Connection
1.
Turn off electrical supply to chiller circuit.
2. Remove the front panel to gain access to electrical
box using a 5/16" (7.9mm) socket wrench or a
flathead screwdriver.
3. Rotate the fan to ensure a proper clearance and
free fan action.
4.
Use 3/8” cable clamp connector or appropriate
conduit connector with nut to connect the electrical
wire to the unit.
5.
Connect ground wire (A) to ground screw (provided).
A
Conduit
Connector
Nut
Screw
Front Panel
Ground
Wire
Electrical
Box