background image

98593C (Rev. B - 9/10)

WCFS*G*L*R     WC8AFSQ*1G     WC8AFSQ*2GJO

PAGE 3

HANGER BRACKETS & TRAP INSTALLATION

1

) Remove hanger bracket fastened to back of cooler by

removing one (1) screw.

2) Mount the hanger bracket and trap as shown in Figure 2.
NOTE:  Hanger Bracket MUST be supported securely.  Add

fixture support carrier if wall will not provide adequate sup-
port.

IMPORTANT:

y

5-1/2 in. (140mm) dimension from centerline of unit to

centerline of trap must be maintained for proper fit.

y

Anchor hanger securely to wall using all mounting holes.

3) Install straight valve for 3/8" O.D. unplated copper tube.

INSTALLATION OF COOLER

4) Hang the cooler on the hanger bracket.  Be certain the

hanger bracket is engaged properly in the slots on the
cooler back as shown in Figure 2.

5) Loosen the two (2) screws holding the lower front panel at

the bottom of cooler base and two (2) screws at the top.
Remove the front panel and set aside.

6) Connect water inlet line--See Note 4 of General Instruc-

tions.

7) Remove the slip nut and gasket from the trap and install

them on the cooler waste line making sure that the end of
the waste line fits into the trap.  Assemble the slip nut and
gasket to the trap and tighten securely.

START UP

Also See General Instructions

8) Stream height is factory set at 35 PSI.  If supply

pressure varies greatly from this, adjust screw, ac-
cessible by removing front panel (Item 7, Fig. 3).
CW adjustment will raise stream and CCW adjust-
ment will lower stream.  For best adjustment, stream
should hit basin approximately 6-1/2” (165mm) from
bubbler.

9) Replace the front panel and secure by retightening

four (4) screws.

PUSH BAR MECHANISM

LEGEND

A)   Note: Water flow direction
B)  Adjust this screw to eliminate mechanism “Free Play” or continuous

flow from bubbler conditions.  (See ADJUSTMENT PROCEDURE)

C)  Stream height adjustment (see note #8)

Water Valve Mechanism - ADJUSTMENT PROCEDURE:

-  Turn adjustment screw (Item 19) “Counter-Clockwise” until water flow from bubbler starts.
-  Turn adjustment screw “Clockwise” until water flow stops, THEN turn an additional 1/2 turn.

NOTE:  Adjustments stated above are viewed from underneath unit (bottom side of dispenser panel
Item 1)
NOTE:   If continuous flow occurs at the end of the compressor cycle, turn cold control (Item 46)
counterclockwise 1/4 turn.

ITEM NO.

PART NO.

Panel - Bottom Dispenser
Block - Pivot
Nut - 1/4 , Self-Threading
Bracket - Side Push
Panel - Right Side
Panel - Left Side
Panel - Front Push
Pushbar - Side & Front
Insert - Push Bar
Bracket - Front Push
Screw - #8 x 5/8" Torx/slotted
Rivet - Drive Type
Bumper - Press Bar
Hex Nut
Bracket - Regulator Mounting
Retaining Nut
Regulator
Holder - Regulator
Screw - Shoulder x 1/2" Lg.
Screw - Regulator Brkt. Mtg.

26588C
51531C

111411743620

22901C

See Color Table
See Color Table
See Color Table

55859C
55947C
22900C
70864C
50212C
51667C
40045C
23003C
15005C
61314C
50986C
70935C
75502C

Item No. 5

Part No.

(w/o hole)

COLOR TABLE

Platinum Vinyl
Stainless Steel
Almond Vinyl
Slate Vinyl

26644C
26637C
26636C
26646C

26659C
26652C
26651C
26661C

26614C
26607C
26606C
26616C

PANEL COLOR

1
2
3
4
5
6
7
8
9

10

11

12
13
14
15
16
17
18
19
20

DESCRIPTION

26629C
26622C
26621C
26631C

26599C
26600C
26601C
26602C

Item No. 5

Part No.

(with hole)

Item No. 6

Part No.

(w/o hole)

Item No. 6

Part No.

(with hole)

Item No. 7

Part No.

FIG. 3

6

11

3

10

7

8

9

9

8

11

12

20

19 B

13

C

11

11

2

14

15

16

17

18

1

3

4

5

A

Reviews: