background image

XP8WQ*1D

PAGE 4

0000001091 (Rev. A - 02/16)

6

24

9

11

10

5

ADJUST THIS SCREW TO ELIMINATE VALVE LEVER "FREE PLAY" 

OR CONTINUOUS FLOW FROM BUBBLER

STREAM HEIGHT 

ADJUSTMENT SCREW

CORRECT STREAM HEIGHT

FIG. 5

PUSH BUTTON VALVE ADJUSTMENT

FIG. 3

FIG. 4

CONDENSER WATER VALVE ADJUSTMENT

The condenser water valve is factory preset for a condenser water outlet temperature of 95° to 105° F.

If actual temperature varies greatly from this, readjust water flow rate at the valve using the following procedures.

 1. 

START UP COMPRESSOR

      This can be accomplished by depressing the cooler push button (See Fig. 1 - Item 2).  Keep water 

       running during the entire readjustment procedure.

2.  

ADJUSTMENT CONDENSER WATER VALVE

       Adjust valve by rotating adjustment stem.  Rotating stem clockwise will increase water flow.  

      Counterclockwise rotation will decrease water flow.  Increasing water flow will result in a lower 

      condenser outlet temperature, while decreasing water flow will result in a higher outlet temperature.  

       Proper adjustment is attained when condenser outlet temperature is 95° to 105° F. 

 

 

 

 

     