PIPE LAYOUT USING BY-PASS AND CLOSE COUPLED FEED AND VENT (fully pumped)
SCHEMATIC PIPE LAYOUT FOR COMBINED GRAVITY DHW AND PUMPED CH
(Showing 2 Zone Valves and By-Pass Loop)
TO DRAIN
OFF TAPS
STOP
VALVE
DRAIN
LOCKSHIELD
VALVE
*MOTORISED
VALVE
22mm
COPPER
ISOLATING
VALVES
22mm
COPPER
15mm
COLD FEED
OPEN VENT
FEED AND
EXPANSION TANK
*MOTORISED
VALVE
PUMP
APPLIANCE
DRAIN
MINIMUM
HEAD 1.2m
150mm
MAX.
*3 WAY
MOTORISED
VALVE
VALVED BY-PASS
LOOP
WATER CONTENT
7 LITRES MINIMUM
*Fit either two motorised
valves, or one 3 way
motorised valve
COLD
WATER
STORAGE
OPEN
VENT
INDIRECT
CYLINDER
AUTOMATIC
AIR VENT
MINIMUM
HEAD 1.2 m
FEED AND
EXPANSION
15mm
COLD
FEED
22mm
OPEN
VENT
28mm
GRAVITY
INDIRECT
CYLINDER
22mm
OPEN VENT
COLD WATER
STORAGE
TO DHW DRAIN
OFF TAPS
STOP
VALVE
DRAIN
28mm
MOTORISED
VALVE 28mm
GRAVITY
DHW
MINIMUM CIRCULATING
HEAD 1.0m
FLOW
RETURN
PUMP
VALVED BY-PASS LOOP
WATER CONTENT
7 LITRES MINIMUM
NOTE: Gravity pipes must rise
continuously towards cylinder
and the vent postioned to
eliminate all air.
ISOLATING
VALVES
MOTORISED
VALVE 22mm
HEATING SYSTEM