12

4.3

PREPARING THE BOILER

a)

Remove the front painted door by sliding it towards the top of
the boiler and then away from the boiler. 

b)

Remove the right hand portion of the case by unscrewing the two
(upper and lower) screws (C) (Fig. 15) and sliding the case away
from the appliance.

c)

Remove the four screws securing the left hand case (D).
Remove the case by sliding it forwards away from the appliance.

15

INNER CASING REMOVAL

i)

Cut the hole in the wall for the flue/air duct.  The diameter
should not be less than 100mm (4in) and must be horizontal.
If the hole is not accessible from the outside of the building, its
minimum diameter should be sufficient to allow the insertion
for the wall liner (130mm (5

1

/

4

in) diameter) which will be

sealed with mortar.  Refer to Fig. 20

(The wall liner is available as an optional extra.)     

j)

Accurately measure the wall thickness, and note this
dimension for use later.

k)

Remove wall mounting bracket from back of boiler by
releasing over-centre clamps on top rear of boiler

l)

Secure the wall mounting bracket in position using the screws
provided.  Ensure that the bracket is the correct way up.

4.4

MOUNTING THE BOILER

Lift the boiler into position, the rear bottom edge of the boiler
locates onto the bottom return of the wall plate.  The top of the
boiler is then pushed back against the top of the wall plate and
the “over centre” clamps are located in their rectangular holes in
the top of the wall plate, clamped in position and secured with the
two split pins provided in the fixing kit.

Remove the combustion chamber front panel by pulling it
forwards out of the appliance, ensure the four flue baffles are
positioned correctly with their top being flat onto the top of the
heat exchanger fins (Key No. 67-Fig 8 page 6).

Remove and discard the wire that retains the heat exchanger baffles.

Replace the combustion chamber front panel ensuring it is fitted
correctly into the two side guides.  Refit the left hand case with the
four screws previously removed.

4.5

AIR FLUE DUCT INSTALLATION

4.5.1

PREPARING THE AIR/FLUE DUCTS

If the wall thickness is less than 800mm (31in) the air/flue duct
may be fitted without access to the external wall providing that the
optional wall liner is used. (This is necessary to seal any cavity and
to allow the sealing ring to pass through from inside but still open
and provide an adequate seal). The wall liner has a tube diameter
of 130mm with a wall thickness of 0.8mm.

a)

Measure the required flue length as shown in Figure 16. Refer
to section 2.5 to determine whether any extension kits are
required. Installations using only the standard ducts or
standard ducts with straight extensions are described in this
section. Installation instructions for all other flue systems are
described in the supplements at the rear of this booklet.

b)

Fit the external sealing ring to the terminal assembly and
assemble the air/flue ducts as shown in Figure 17. The
standard duct is always used at the entry/exit to the boiler,
and the sliding (telescopic) terminal is always slid into the end
of the standard or extension duct (where appropriate). 

c)

Achieve the correct flue length using Figure 18 as a guide.
Note that the flue length is measured to the inside of the
external wall sealing ring. In most cases it will be possible to
achieve the required flue length without cutting the ducts,
however where necessary the plain ends of the extension ducts
may be cut. 

Never cut the swaged end

, and always

ensure that the cut is square and free of burrs or debris. The
minimum overlap of the telescopic section is 50mm (2in).

d)

Assemble the flue using Figure 19 as a guide. It is important
that the steps are carried out in the order stated in Figure 19.
When securing the ducts in position always drill two 3.3 mm
diameter holes in each extension air duct joint and use the self
tapping screws provided to secure each joint.

NOTE IT IS ESSENTIAL THAT THE TERMINAL IS FITTED THE
CORRECT WAY UP See Fig 17 (i.e. rainshield at the top).

16

MEASURING THE EXACT FLUE LENGTH

FAN OUTLET
EXTERNAL
Dia. 60mm

TOTAL FLUE LENGTH FROM
FLUE OUTLET CENTRE TO
OUTSIDE WALL FACE:
= LENGTH  

L

WALL

L

D

C

C

CONTROL
KNOB

Summary of Contents for Best db 30

Page 1: ...st 50 G C No 41 333 52 Best 60 G C No 41 333 53 SUPPLY PRESSURE 20 mbar 0 0 8 6 TO BE LEFT WITH THE USER FOR USE WITH NATURAL GAS ONLY G20 CAST IRON WALL MOUNTED FAN ASSISTED BOILER B R I T I S H M A...

Page 2: ...ne radiator which should be fitted with lockshield valves only Gravity It is recommended that when used on a gravity domestic hot water application a Honeywell C Plus plan or equivalent is fitted to t...

Page 3: ...kw 8 79 11 72 14 65 17 58 Btu hr 30000 40000 50000 60000 kw 5 86 8 79 11 72 Btu hr 20000 30000 40000 60000 kw 11 13 14 75 18 43 22 37 Btu hr 37975 50315 62893 76326 kw 7 71 11 42 14 84 Btu hr 26316 3...

Page 4: ...CT VERTICAL SOCKET 90 ELBOW NON FLANGED STANDARD DUCT 90 ELBOW NON FLANGED EXTENSION DUCT 2 d FLUE WITH 90 BEND TERMINAL DUCT STANDARD DUCT FLANGED ELBOW 90 ELBOW NON FLANGED EXTENSION DUCTS 2 e HORIZ...

Page 5: ...a Standard flue assembly using either side or rear outlet Flue length L measured from the boiler outlet centre line to the outside wall face max 820mm Maximum wall thickness Wr Rear outlet 620mm max M...

Page 6: ...rd flue assembly Equivalent Length Shown is 3045mm Where Lb is 919mm and Lw is 820mm Lw is measured to the outside wall face Fig 4b As 4a but with one additional extension in length Lb Equivalent Leng...

Page 7: ...t length shown is 2325mm Where Lh measured from the top of the boiler casing to the centre line of the extra elbow 551mm and length Lw measured from the centre line of the extra elbow to the outside w...

Page 8: ...LOADED DIAGRAM Drawing amended 7 05 99 79 48 17 47 59 12 4 11 7 13 8 80 5 64 63 81 37 38 39 60 43 21 62 77 19 67 68 66 76 78 26 25 56 49 19 71 75 49 65 73 46 34 35 36 61 55 28 44 15 23 18 19 22 14 30...

Page 9: ...T be installed so that the terminal is exposed to the external air 3 1 STATUTORY REQUIREMENTS 3 2 BOILER LOCATION SAFETY INSTALLATION AND USE REGULATIONS 1984 AS AMENDED It is the law that all gas app...

Page 10: ...temperature difference of 11 C between the flow and return pipes on the boiler The resistance through each model of boiler at the required flow rate may be found in Section 2 3 3 7 WATER SYSTEMS An o...

Page 11: ...MOTORISED VALVE VALVED BY PASS LOOP WATER CONTENT 7 LITRES MINIMUM Fit either two motorised valves or one 3 way motorised valve COLD WATER STORAGE OPEN VENT INDIRECT CYLINDER AUTOMATIC AIR VENT MINIM...

Page 12: ...dequate clearance for fitting the right hand inner case The central heating flow must be connected to the 22mm connection on the top manifold The central heating return must be connected to the 22mm c...

Page 13: ...ned and make the necessary hole s in the ceiling roof Proceed to k f ADDITIONAL ELBOW OR FLANGED DUCT WITH ELBOW Using the wall mounting template and the dimensional information given in section 2 4 2...

Page 14: ...se with the four screws previously removed 4 5 AIR FLUE DUCT INSTALLATION 4 5 1 PREPARING THE AIR FLUE DUCTS If the wall thickness is less than 800mm 31in the air flue duct may be fitted without acces...

Page 15: ...n 425mm L 76mm MAX 319mm 17mm 19 ASSEMBLING THE FLUE SYSTEM TOP 1 SLIDE EXTERNAL SEALING RING UPTO FLUE TERMINAL L 2 STANDARD DUCT Push ducts fully over elbow and drill two 3 3mm dia holes Secure with...

Page 16: ...SEALING RING FIBRE SEAL FITTED 4 5 3 INSTALLING THE AIR FLUE DUCT FROM OUTSIDE THE BUILDING Flue hole diameter 100mm wall liner not necessary a Secure the flue elbow with seal to the appliance using 4...

Page 17: ...conomical heating system However should the boiler be installed for use with a combined PUMPED CH GRAVITY DHW system the small jumper plug in the front of the control box must be repositioned in the g...

Page 18: ...HEATING VALVE HOT WATER VALVE 230V MAINS INPUT OR A B C 4 5 6 8 NOT USED 5 2 1 9 3 8 2 1 10 3 1 2 3 L N E BROWN BLUE GREY ORANGE GREEN YELLOW BROWN BLUE GREY ORANGE GREEN YELLOW 1 3 2 1 2 4 5 2 1 5 1...

Page 19: ...THERMOSTAT 2 1 E N L L N E 9 8 3 2 1 9 2 3 BOILER PUMP 6 3 N L 3 4 N L 6 4 3 2 1 Honeywell ST699B 1002 Link L 5 8 ST 799A ST6400 ST6300 PROGRAMMER 2 Pump Live 1 Switched Live L Permanent Live 230V 50...

Page 20: ...he boiler and system should now be allowed to reach its maximum working temperature and examined for water leaks o Turn off the heating system and drain whilst still hot p Refill and vent ensuring all...

Page 21: ...of the boiler complete with its electrodes d Inspect and if necessary clean the burner assembly If either electrode shows signs of damage or wear replace it e Inspect and if necessary clean the main i...

Page 22: ...ISOLATE the mains electrical supply remove the front painted panel by sliding up and then away from the boiler remove the right hand portion of the inner case by first pulling off the control knob the...

Page 23: ...e the valve manifold assembly from the boiler 7 9 MAIN BURNER a Remove the four screws securing the left hand inner case Remove the case by sliding it forwards and off the appliance b Remove the combu...

Page 24: ...EN YELLOW RED RED WHITE WHITE PINK BROWN BLUE GREEN WHITE GREEN YELLOW GREEN YELLOW BLUE BROWN BLACK PURPLE BLUE RED WHITE WHITE RED BLUE RED BROWN RED BLACK BLACK GREEN YELLOW 2 1 N L ORANGE BLACK OR...

Page 25: ...ignition lockout turn thermostat to maximum setting and ensure programmer is switched on before pressing reset button YES NO Replace the fan Is there 230V at the fan motor Replace the fan YES NO Chec...

Page 26: ...rode All 1 500574 5 Gas Valve Without Ignition Device All 1 500569 6 Ignition Device For Gas Valve All 1 500570 7 Aquastat PCB All 1 600513 8 Thermistor All 1 500572 9 Overheat Cut Off Device All 1 50...

Page 27: ...nd flue are to be positioned and make the necessary hole in the wall s for the air flue duct as defined in section 4 2 c Install the boiler as described in section 4 with the exception of the flue sys...

Page 28: ...ax 01787 474588 SERVICE HOTLINE 01203 351424 Halstead Boilers are continuously improving their products and therefore reserve the right to change specifications without prior notice and accept no liab...

Reviews: