6
PART NO: 956085
2.5.4
KIT D EXTERNAL VERTICAL FLUE - (C33)
3e
Suitable for installations if the appliance can’
t be repositioned
and where other horizontal flue options may causes some
nuisance to neighbours or buildings. The flue kit contains some
additional 45° elbows and extension ducts as well as a special
wall bracket to pass the guttering (see Figure 3e). The concentric
Maximum flue resistance permitted for an open flued system = 55 Pa.
Flue Component
Flue Resistance
Part
(Pa)
Number
Air inlet Assembly (r
equired)
2
-
60/80 Adaptor (required)
1
-
Terminal (required)
0.5
-
91.5° Elbow (80) (required)
2
-
80 diameter Corrugated (required)
1.5 per metre
-
80 mm diameter straight duct
0.5 per metre
-
93° Boiler to flue flanged elbow
3
956086
Vertical turret socket
0.5
956087
93° inline elbow (60/100)
3
956091
45° inline elbow (60/100)
1.5
956090
Centralising brackets
Chimney terminal
93 flanged elbow (concentric)
with sampling point
Ø60/100mm concentric
chimney adaptor pipe.
In replacement installations,
the chimney has to be
cleared of debris and
all flue parts.
Chimney
plate
Flexible corrugated plastic flue liner
Ø80mm according to EN 14471
Max. length 30m.
Min. length 5m.
KIT E
Chimney flue liner kit - Part no. 956082
3f
A
flue system can be built up from the components
detailed in the table, but the total flue resistance must
not exceed the maximum stated.
3d
flue will be r
outed vertically alongside the outside wall to above
the roofline. Special seals are required to prevent rainwater
penetrating the pipe joints.
For installation details refer to the flue kit instructions.
This kit is suitable for open flue application in accordance with BS5440
where a room sealed flue installation is impractical. The kit comprises of a
flue adaptor from the appliance to the chimney, a flexible plastic flue liner
with connection parts and chimney terminal (see Figure 3f). Where an
open flue system is used, then an air vent must be provided in the same
room or internal space as the flue duct air inlet, see section 3.4.
For installation details refer to the flue kit instructions.
(B23) – PART NO. 956082
2.6
KIT E CHIMNEY FLUE LINER KIT