WARNINGS
Gas Leak or Fault
If a gas leak or fault exists or is suspected, turn the boiler
mains electrical supply off and turn off the gas supply at the
meter. Consult your local gas company or your local
installation/servicing company.
Clearances
If fixtures are positioned close to the boiler, space must be
left as shown in diagram 3.1. Enough space must also be
left in front of the boiler to allow for servicing.
Sheet Metal Parts
This boiler contains metal parts (components) and care
should be taken when handling and cleaning, with particular
regard to edges.
Sealed Components
Under no circumstances must the User interfere with any
sealed component as this could result in a potentially
dangerous situation arising.
Electrical Supply Failure
This boiler must be earthed.
The boiler will not work without an electrical supply.
Normal operation of the boiler should resume when the electrical
supply is restored.
Reset any external controls, to resume normal operation of the
central heating.
If the boiler does not resume normal operation turn the mains
reset switch off and on. If the boiler does not resume normal
operation after this the overheat stat may have operated. The
overheat stat would only operate under abnormal conditions
and, under these circumstances; it would be advisable to
consult your installation / servicing company.
Protection Against Freezing
The boiler has a built in frost protection programme as long as
the electricity and gas are left switched on.
This device operates the burner and system pump when the
temperature inside the boiler falls to 3
0
C.
Any other exposed areas of the system should be protected by
a separate frost thermostat.
If the mains electricity and gas are to be turned off for any long
periods during severe weather, it is recommended that the
whole system, including the boiler, should be drained to avoid
the risk of freezing. Make sure that, if fitted, the immersion
heater in the cylinder is switched off.
If you have a sealed water system contact your installation/
servicing company as draining, refilling and pressurising MUST
be carried out by a competent person.
As a safety feature the boiler will stop working if the condensate
drain becomes blocked. During freezing conditions this may be
due to the forming of ice in the condense drain external to the
house. Release an ice blockage by the use of warm cloths on
the pipe. The boiler should then restart. Contact your installation/
servicing company if the fault persists.
Boilers Installed in a Compartment or
Cupboard
If the boiler is fitted into a compartment or cupboard it does not
require ventilation openings.
Do not use the compartment or cupboard for storage.
Boiler Casing
Do not remove or adjust the casing in any way, as incorrect
fitting may result in incorrect operation or failure to operate at all.
Condensate Drain
The condensate drain, see section 7.3, must not be modified or
blocked.
Pluming from flue terminal
Like all condensing boilers this appliance will produce a plume
of condensation from the flue terminal in cool weather. This is
due to the high efficiency and hence low flue gas temperature
of the boiler. It is normal and not a fault indication.
Cleaning
This appliance contains metal parts and care should be taken
when handling and cleaning with particular regard to edges.
The boiler casing can be cleaned using a mild liquid detergent
with a damp cloth, then a dry cloth to polish.
Do not use any form of abrasive or solvent cleaner as you may
damage the paintwork.
Maintenance and Servicing
For the continued efficient and safe operation of the boiler it is
recommended that it is checked and serviced at regular intervals.
The frequency of servicing will depend upon the installation
conditions and usage, but in general, once a year should be
enough.
If this appliance is installed in a rented property in the UK there
is a duty of care imposed on the owner of the property by the
current issue of The Gas Safety (Installation and Use)
Regulations, Section 35.
Servicing/maintenance should be carried out by a competent
person in accordance with the rules in force in the countries of
destination.
To obtain service, please call your installer or Halstead Boilers
using the telephone number on the front cover of this booklet.
Please be advised that the installation engineer on completion
of commissioning and servicing should complete the ‘Benchmark’
logbook.
All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boiler Logbook. You can check your installer is CORGI registered
by calling CORGI direct on: - 01256 372300.
Replacement Parts
If replacement parts are required contact Halstead Boilers
using the telephone number on the front cover of this booklet.
Please quote the name of the appliance, this infomation will be
on the name badge on the front of the appliance.
If in doubt seek advice from the local gas company or Halstead
Boilers using the telephone number on the front cover of this
booklet.