PSx3xxDN Instruction Manual
11
Name
Attr.
No.
Function
Range of
value
Back
up
Delivery
State
R/W
lower limit
23
minimum permissible target position
permissible values: upper limit -
0...250*spindle pitch + reference value
31 bit
yes
1200
R/W
maximum
start-up
torque
24
value in cNm
see table
16 bit
yes
see
table
R/W
time period
for start-up
torque
25
value in msec
10...1000
16 bit
yes
200
R/W
rpm limit for
aborting run
26
value in % of the target rpm
30...90
16 bit
yes
60
(PSx3110
and
PSx3125)
30
(all others)
R/W
time elapsed
until speed
falls below
rpm limit for
aborting run
27
value in msec
50...500
16 bit
yes
200
R/W
length of loop 31
minimum number of increments which the
drive moves in a pre-defined direction
when approaching a target position
value in increments (value = 0
no loop)
0.025…1
rotations
or 0
32 bit
yes
250
R/W
maximum
rpm, counter-
clockwise
32
value in rpm
see table
16 bit
yes
see
table
R/W
maximum
rpm,
clockwise
33
value in rpm
see table
16 bit
yes
see
table
R/W
size of
individual
increment
34
number of increments when external keys
pressed (or when activating a jog run bit)
for a short-time
1...100
16 bit
yes
1
R/W
idle period for
manual run
35
Span of time a manual run key must be
pressed (or a jog run bit must be
activated) in order to begin a manual run
value in steps of 5 msec
20...2000
16 bit
yes
200
R/W