PSx3xxDN Instruction Manual
33
5 Technical data
Ambient conditions
ambient temperature
0 °C to +45 °C
storage temperature
-10 °C to +70 °C
shock resistance according to
DIN IEC 68-2-27
50 g 11 ms
resistance to vibration
according to DIN IEC 68-2-6
10 Hz to 55 Hz 1.5 mm
55 Hz to 1000 Hz 10 g
10 Hz to 2000 Hz 5 g
EMC standards
CE
conformity
CE declaration of conformity available upon request
protection class
PSE
IP 54
PSS
IP 65
PSW
IP 66 (in operation)
IP 68 (at standstill)
duty cycle
Device model
Duty cycle in %
Base time in sec.
PSE34xx
PSE30xx to 33xx
PSS
PSW
20
30
20
20
300
300
600
600
Electrical data
nominal power output
PSx30xDN, PSx31xDN,
PSE31xxDN
25 W with 30 % duty cycle
PSx32xDN, PSx33xDN
35 W with 30 % duty cycle
PSE34xxDN
100 W with 20 % duty cycle
supply voltage
24 VDC ±10 % (supply voltages for motor and control
unit are galvanically isolated)
advice: use regulated power supplys
nominal current, control unit
0.15 A
nominal current, motor
PSx30xDN, PSx31xDN,
PSE31xxDN
2.2 A
PSx32xDN, PSx33xDN
3.0 A
PSE34xxDN
7.8 A
positioning resolution
0.9°
positioning accuracy
0.9°
CAN protocol
DeviceNet (ODVA CIP Networks Library Volume One
Edition 3.1 and Volume Three Edition 1.3)
CAN address setting via decade switch/bus:
addresses 0...63
baud rate setting via sliding switch/bus:
125 kBaud, 250 kBaud, 500 kBaud
(CAN address and baud rate setting for software
versions starting from version 147)
In some stainless steel variants (e.g. the PSx395RD) the
protective cap is not present. In this case, device
address and baud rate can only be set via bus!
absolute value acquisition
optical - magnetic