Bit 1
:
drag error
This bit is set:
- if during a run (except in the braking phase) the difference between actual
target position and actual position exceeds the value which has been set with
Par. 44
This bit is reset:
- with each new run command
Bit 2
:
reverse jog key active
This bit is set:
- if Pin 3 on the key connector is connected with Pin 1 (+24V)
This bit is reset:
- if Pin 3 on the key connector is deconnected from Pin 1 (+24V)
Bit 3
:
forward jog key active
This bit is set:
- if Pin 2 on the key connector is connected with Pin 1 (+24V)
This bit is reset:
- if Pin 2 on the key connector is deconnected from Pin 1 (+24V)
Bit 4
:
motor power present
This bit is set:
- if the supply voltage to the motor is above the Umot limit (Par. 108) and
below 30V
This bit is reset:
- if the supply voltage to the motor is below the Umot limit or above 30V
Bit 5
:
positioning run aborted
This bit is set:
- if a positioning run is aborted because release in the control word has been
withdrawn or because of an invalid bit combination in the control word
This bit is reset:
- with each new run command
Bit 6
:
drive is running
This bit is set:
- when the drive is rotating
This bit is reset:
- when the drive is on standstill
Bit 7
:
temperature exceeded
This bit is set:
- if the internal device temperature device exceeds the limit value (Par. 110)
This bit is reset:
- if the internal device temperature falls below the limit value by 5°C
Bit 8
:
movement opposite loop direction
This bit is set:
- after power-up or a reset (a lash in a driven spindle which might be present is
not yet eliminated)
- when commanding a positioning run or a manual run in opposite of the loop
direction
- when commanding a positioning run or a manual run, when no loop is
configured (Par. 42 is zero)