Instruction Manual PSx3xxPN
17
Name
Par.
Number
Function
Type/
Range
Back
up
Delivery
State
R/W
Parameter group “others” (continued)
delivery state 96
writing “-6”:
resets the drive (equal to switching off
and on again the control power supply)
writing “-5”:
sets the values of all parameters to the
delivery state, saves all parameters in the
EEPROM, afterwards positioning run to
the middle of the measurement range *)
(device name and IP address stay
unaffected)
writing “-4”:
sets the values of all parameters to the
values which are saved last by the user,
afterwards positioning run to the middle of
the measurement range *)
(device name and IP address stay
unaffected)
writing “-3”:
sets the values of all parameters to the
delivery state, erases the device name
and the IP address and saves all
parameters in the EEPROM
writing “-2”:
sets the values of all parameters to the
values which are saved last by the user,
without saving the parameters in the
EEPROM (device name and IP address
stay unaffected)
writing “-1”:
sets the values of all parameters to the
delivery state, without saving the
parameters in the EEPROM (device name
and IP address stay unaffected)
writing “1”:
saves all parameters in the EEPROM
reading directly after boot:
0
content of memory correct
≠ 0
content of memory incorrect
reading after saving:
0
saving finished successfully
≠ 0
saving is still in progress or is
finished incorrectly (the time for saving is
up to 200 msec)
Changes only possible when at standstill
-
6…-1
or 1
(writing)
0...2
(reading)
±15 bit
no
R/W
*) In cyclic process data exchange, the control word is ignored during a run to the middle of
the measurement range (unless it changes). Thus a run to the middle of the measurement
range may be interrupted by a change of the control word. Run commands issued before the
run to the middle of the measurement range will not automatically restart after finishing the