Instruction Manual PSx3xxPL
16
Name
Index
number
Function
Range of
value
Back
up
Delivery
State
R/W
delivery state 204F
writing “-2”:
sets the values of all parameters to the
values which are saved last by the user,
without saving the parameters in the
EEPROM
writing “-1”:
sets the values of all parameters to the
delivery state, without saving the
parameters in the EEPROM
writing “1”:
saves all parameters in the EEPROM
reading directly after boot:
0
content of memory correct
≠ 0
content of memory incorrect
reading after saving:
0
saving finished successfully
≠ 0
saving is still in progress or is
finished incorrectly (the time for saving is
up to 200 msec)
Changes only possible when at standstill
-2, -1
oder 1
(writing)
0..2
(reading)
15 bit
no
R/W