Description of CANopen
7100.006424_Bus description_PSD4xx_CA_H_ENG
20
08.04.2020
Delivery
state
Writing a “-1”:
Resets all parameters to the
delivery states (without changing
the CAN address and baud rate),
without saving the parameters in
EEPROM. The drive then
performs a start-up loop and
positions itself in the middle of the
measurement range.
Writing a “1”:
Saves the parameter in EEPROM
Writing a “0”:
No action
Reading after booting:
0
Memory content correct
≠ 0
Memory content incorrect
Reading after saving:
0
Saving successfully
completed
≠ 0
Saving is not yet complete
or terminated with errors (saving
can take up to 2000ms)